Download Code Alarm CR3 User manual
Transcript
Reg 55 Setting Name Notify of No-Read (notifyOfReadFailure) Default (hex) 0 Comment 0: Disable 1: send “r” packet on No-Read (See “r” packet in Section 5.2.) 0x100xx: post event on No-Read , where the lower 8 bits specify the event number. For example, 0x10009 to post Event 0x09. The following example will use a stored code and stored code event to output “No Read” on read failure. B% 48%01X%1d%02>No%0dRead%00 P%5510048 59 Beep/Vibration Duration (beepDuration_ms) CR2/CR3: 64 (#100) Output when no decode was achieved: No (%0d inserts carriage return) Read Valid Range: 0 to 7FFFFFFF Milliseconds Also see registers: 26, a7 CR1200: 50 (#80) 1 6a UPC Symbology (enableUpc) 6b Code 39 Symbology (enableCode39) 1 6c Code 93 Symbology (enableCode93) Code 128 Symbology (enableCode128) Interleave 2 of 5 Symbology (enableInterleave2of5) 1 Codabar Symbology (enableCodabar) Code 39 CheckSum (code39Checksum) 1 6d 6e 6f 70 1 1 0 0: Disable 1: Enable Also see registers: 4d, 4e, 74 0: Disable 1: Enable Also see register: 70 0: Disable 1: Enable 0: Disable 1: Enable 0: Disable 1: Enable Also see registers: 71, c9 0: Disable 1: Enable Binary Dip Switch Bit Controls 0 Code 39 Checksum Checking 1 Strip Checksum From Output Value 0: Disable 1: Enable 0: Disable 1: Enable Also see register: 6b V002450_25_CR1200-CR2-CR3-CR2500-CR3500_Interface_Configuration_Document_CLIENT.docx 2011-04-27 Page 33 of 65 © 2011 The Code Corporation • 14870 S. Pony Express Rd., Suite 200, Bluffdale, UT 84065 • (801) 495-2200 • FAX (801) 495-0280