Download Sharp MD-S10E Specifications
Transcript
CLADDING & LINING Louvre Blade width: 150 mm nominal. Glass Louvre Blades: To AS 1288. Metal Louvre Blades: Proprietary pre finished metal blades complying with the design requirements. 8.14 INSTALLATION Install flashings and weatherings so that water is prevented from entering the building. Finish the installation with trims etc., to make neat, clean junctions at adjoining building surfaces. 8.15 COMPLETION Remove temporary protection and ensure smooth and free operation of the assemblies. 9.CLADDING AND LINING 9.1 GENERAL Cross references Refer to the following sections: • Tiling, for waterproofing of wet areas. • Insulation and Sarking, for wall sarking requirements. • Timber and Steel Construction, for compressed fibre cement flooring. 9.2 MATERIALS AND COMPONENTS Flashing material Standard: To AS/NZS 2904. Sarking Heavyweight reinforced aluminium foil complying with AS/NZS 4200.1. Proprietary Item: Bradford Thermofoil 753 (heavy weight). Fasteners Steel nails: Hot-dip galvanized to AS/NZS 4680. Self-drilling screws: To AS 3566, corrosion resistance class 4 in tropical areas and class 3 in inland areas. Finish: Prefinish exposed fasteners with an oven baked polymer coating to match the cladding. 9.3 PLASTIC CLADDING Standard Unplasticised polyvinyl chloride (UPVC) sheet: To AS 4256.4. Glass fibre reinforced polyester (GRP) sheet: To AS 4256.3. Polycarbonate: To AS 4256.5. Provide a proprietary system of interlocking planks including all accessories fixed in accordance with the manufacturers requirements and the Northern Territory Deemed to Comply standards. Installation Standard: To AS 1562.3. 9.4 FIBRE CEMENT CLADDING Standard General: To AS/NZS 2908.2, type A, category 3. Plank cladding Type: Provide a proprietary system of single faced fibre cement planks 7.5 mm thick. Joints and edges: Metal joining clips and UPVC moulded trims to finish at door and window frames. Corners: Preformed metal joining pieces. Sheet cladding Type: Provide single faced fibre cement sheets 6 mm thick. Joints, corners and edges: UPVC extrusions or V butt joints. Use a Super Alcor backing strip behind vertical V butt joints and a Z section zincalume trim at horizontal joints. Eaves & soffit lining Type: Provide a proprietary system of single faced fibre cement sheets 6 mm thick. Joints: UPVC extrusions or V butt joints. Installation: Screw fix at 150 mm crs with proprietary self embedding head screws in accordance with the manufacturers instructions and the Northern Territory Deemed to Comply standards. Screw Types To metal 1mm to 1.6 mm thick: Blue Hornet self embedding head screws. To timber and to metal under 1 mm thick: Streaker No. 8 x 20 mm self embedding head screws. 9.5 COMPRESSED FIBRE CEMENT CLADDING Standard: To AS/NZS 2908.2, type A, category 5. Cladding: 9 mm thick compressed fibre cement sheets. Joints: Expressed joints - 10 mm gaps with EDPM gasket backing strips. Fixing: Recessed countersunk screws in pre-drilled holes, filled with epoxy compound and sanded smooth in accordance with the manufacturers technical data. 9.6 METAL CLADDING Cladding Provide a proprietary system of prefinished profiled metal cladding complete with accessories, trim and flashings. Fixing: Fix in accordance with the manufacturers instructions and the Northern Territory Deemed to Comply standards. Penetrations: Flash all pipes and ducts, etc., passing through the cladding and trim with colour matched material to ensure weathertight joints. Design and installation Standard: To AS 1562.1. STANDARD SPECIFICATION - BUILDINGS DPI REFERENCE TEXT - APRIL 2009 PAGE 21 Specifications March 2009.indd 21 11/03/2009 11:47:11 AM