Download Benchmark BMA 220 SP - SOL Technical data
Transcript
1.0 DESIGN 1.3 SYSTEM DETAILS Heating System Expansion Vessel Requirements The BoilerMate expansion vessel is pre-charged to 1.0 bar. The maximum water content of the heating system (boiler + radiators + connecting pipework + primary coil but NOT store volume) must not be greater than those shown in the table below. A figure of 4.5 litres/kW of installed radiator capacity can be used for a preliminary assessment of the water content of the heating system. The values presented in the table are based on a maximum boiler flow temperature of 93oC. The expansion vessel must be suitable to accommodate the change in volume of the water in the system when heated from 10oC to 110oC as specified in BS 5449: 1990 clause 16.2. The primary heating coil and pipework volumes are shown in the table in 1.2 Technical Data. In normal circumstances an initial vessel and system charge pressure of 1 bar is suitable for most domestic purposes. The minimum system pressure should not be less than the static head plus 0.5 bar i.e. the height of the highest point in the system above the expansion vessel plus a margin of 0.5 bar. If the system volume is greater than that shown in the table at the selected operating conditions then an additional expansion vessel must be fitted. 12 Litre Vessel i.e. BMA 120/140/180 Maximum Recommended Heating System Volumes Safety valve setting (bar) 3.0 Vessel charge pressure (bar) 0.5 1.0 1.5 Initial system pressure (bar) 0.5 1.0 1.5 1.0 1.5 2.0 1.5 2.0 Maximum permitted system volume (litres) 140 80 40 110 60 27 70 35 25 Litre Vessel i.e. BMA 200/220 Maximum Recommended Heating System Volumes Safety valve setting (bar) 3.0 Vessel charge pressure (bar) 0.5 1.0 1.5 Initial system pressure (bar) 0.5 1.0 1.5 1.0 1.5 2.0 1.5 2.0 Maximum permitted system volume (litres) 270 160 85 200 115 50 140 65 Page 18