Download Altera UG-01080 User guide
Transcript
UG-01080 2015.01.19 Transceiver PHY Reset Controller Interfaces 17-7 Figure 17-2: Transceiver PHY Reset Controller IP Core Top-Level Signals Generating the IP core creates signals and ports based on your parameter settings. Transceiver PHY Reset Controller Top-Level Signals PLL and Calibration Status PLL Control Clock and Reset pll_locked[<p>–1:0] pll_select[<p*n>–1:0] (1) tx_cal_busy[<n>–1:0] rx_cal_busy[<n>–1:0] rx_is_lockedtodata[<n>–1:0] tx_manual[<n>–1:0] rx_manual[<n>–1:0] tx_digitalreset[<n>–1:0] tx_analogreset[<n>–1:0] tx_ready[<n>–1:0] rx_digitalreset[<n>–1:0] rx_analogreset[<n>–1:0] rx_ready[<n>–1:0] pll_powerdown[<p>–1:0] clock reset TX and RX Resets and Status PLL Powerdown Note: (1) n=1 for pll_select signal width when a single TX reset sequence is used for all channels. Note: PLL control is available when you enable the Expose Port parameter. Table 17-4: Top-Level Signals This table describes the signals in the above figure in the order that they are shown in the figure. Signal Name pll_locked[<p>1:0] pll_select[<p*n>1:0] Direction Clock Domain Description Input Asynchronous status Provides the PLL locked status input from each from TX PLL. PLL. When asserted, indicates that the TX PLL is locked. When deasserted, the PLL is not locked. There is one signal per PLL. Input Synchronous to the Transceiver PHY Reset Controller input clock. Set to zero when not using multiple PLLs. When you select Use separate TX reset per channel, this bus provides enough inputs to specify an index for each pll_locked signal to listen to for each channel. When Use separate TX reset per channel is disabled, the pll_ select signal is used for all channels. n=1 when a single TX reset sequence is used for all channels. tx_cal_busy[<n> 1:0] Input Transceiver PHY Reset Controller IP Core Send Feedback Asynchronous This is the calibration status signal that results from the logical OR of pll_cal_busy and tx_ cal_busy signals. The signal goes high when either the TX PLL or Transceiver PHY initial calibration is active. It will not be asserted if you manually re-trigger the calibration IP. The signal goes low when calibration is completed. This signal gates the TX reset sequence. The width of this signals depends on the number of TX channels. Altera Corporation
Related documents
Altera UG-01080 User guide
Altera Transceiver PHY IP Core User Guide
Arria 10 Transceiver PHY User Guide
Altera PHY IP Core User guide
Altera PHY IP Core User guide
Altera Stratix GX User guide
JESD204B IP Core User Guide
CPRI MegaCore Function v12.1 SP1 User Guide
SerialLite III Streaming MegaCore Function User Guide
Altera UG-01080 User guide
Triple-Speed Ethernet MegaCore Function User Guide
XT 74 IP - centrais digistar e intelbras.