Section 7-1
Monitoring Operation and Modifying Data
Incrementing and
Decrementing
00000
00000
TIM
000
00201SRCH
TIM
000
00201 TIM
DATA
#0123
00201 TIM
DATA
T000 #0123 #????
00201DATA ? U/D
T000 #0123 #0123
Current SV (during
change operation)
SV before the change
00201DATA ?
T000 #0123 #0122
00201DATA ?
T000 #0123 #0123
00201DATA ?
T000 #0123 #0124
00201DATA ?
T000 #0124 #????
00201 TIM
DATA
#0124
Returns to original display
with new SV
253