INSTALLATION 3.3.5 3 Inputs Two opto-coupled and polarity insensitive inputs are available on the 25-pin connector. The pinout is the following: Pin 18 19 6 10 Name EXT_TRIG A EXT_TRIG B IN 2A IN 2B Function External trigger (polarity insensitive) External trigger (polarity insensitive) Input signal 2 (polarity insensitive) Input signal 2 (polarity insensitive) When current flows through the EXT_TRIG input, the yellow LED (Figure A, 6) is on. The External Trigger can be used in One Shot Mode or in Phase Mode. Its main functions are: • acquisition trigger in One Shot Mode • reading phase-ON/reading phase-OFF command in Phase Mode The main functions of the general purpose Input 2 are: • second external trigger in Phase Mode • match code storage command when the Match Code option is enabled These inputs can be driven by either a PNP or NPN type command. The connections are indicated in the following diagrams: Polarity insensitive inputs assure full functionality even if pins A and B are exchanged. NOTE Vext MATRIX 30 Vdc Max. ~ + + V OUT A VCC USER INTERFACE I in - ~ GND B Figure 49 - Input PNP Command Using External Power MATRIX USER INTERFACE VS 9 A VCC ~ + + V OUT - ~ GND B 25 GND Figure 50 - Input PNP Command Using Matrix-2000™ Power 37