Download Selectronic SP Pro Technical data

Transcript
Data sheet
Powador
10.0 TL3
12.0 TL3
14.0 TL3
18.0 TL3 NEW
Data sheet
Powador
10.0 TL3
12.0 TL3
14.0 TL3
18.0 TL3
NEW
Powador
10.0 TL3 | 12.0 TL3
14.0 TL3 | 18.0 TL3
The power plants of the future.
The transformerless three-phase inverters Powador 10.0 TL3 to 18.0 TL3.
3D efficiency diagram for Powador 14.0 TL3
95
97
700
650
UDC[V]
Multilingual menu
97
600
550
95
Graphical display
97
97
500
93
450
97
96
97
94
400
Integrated web server
350
1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 11000 12000
PAC [W]
USB connection for updates
Efficiency characteristic curve for Powador 14.0 TL3
100
η [%]
Conforms to the German Medium
and Low Voltage Directives
99
755 V
98
97
96
95
755 V
94
η
93
η
92
η
91
90
0
2000
4000
6000
PAC [W]
8000
10000
Max
Euro
CEC
= 98.0
= 97.6
= 97.8
12000
Subject to technical changes. Errors and omissions excepted.
Integrated web server
Two MPP trackers, symmetrical
and asymmetrical loading possible
98
750
96
43
98.0 % efficiency
800
The power plants of the future.
Graphical display
EN 5000064-05-120602
strings can be connected per MPP controller, i.e. 4 strings for each unit.
94
ware can be downloaded free of charge
from the download area of www.kaconewenergy.de/service. The yield data can
be called from the web server or via USB
The rated input voltage range of 350 to
for evaluation. The integrated data log800 V is particularly broad (420 to 800 V
ger can also be connected directly to the
for the Powador 18.0 TL3). The inverters
Powador web internet portal for professwitch to the grid from 250 V, and, when
The
transformerless
three-phase
inverters
Powador
10.0 TL3 to 18.0 TL3.
sional evaluation and visualisation of the
in operation, they still feed in at 200 V.
They operate using two separate MPP
inverter data.
This means that solar yields are optimum
trackers that can handle both symmefor comparatively small areas such as
trical and asymmetrical loads to allow
ware can be downloaded free of charge
strings can be connected per MPP conPhotovoltaic systems of up to several
A number of country-specific default
dormers or carports but they also opefor optimum adjustment. Each tracker
from the download area of www.kacotroller, i.e. 4 strings for each unit.
hundred kilowatts can be designed exsettings are programmed into the inverrate for more of the day. The peak efficiis able to process virtually all of the AC
newenergy.de/service. The yield data can
tremely flexibly in small, highly efficient
ters. These are easy to select during onency is 98 % and the European efficiency
output. This allows for all typical requibe called from the web server or via USB
The rated input voltage range of 350 to
units with the transformerless threesite installation. The interface language
is also above average. The compact derements of complex designs to be fulfilfor evaluation. The integrated data log800 V is particularly broad (420 to 800 V
phase inverters Powador 10.0 TL3 to
can be selected separately. The inverters
sign weighing only 40 kg combined with
led; on the one hand, for example, full
ger can also be connected directly to the
for the Powador 18.0 TL3). The inverters
18.0 TL3.
conform to the German Medium and
the DC connection via solar connectors
configuration of an east/west-facing roof
Powador
web internet portal for professwitch to the grid from 250 V, and, when
Powador
Low Voltage Directives
and support the
makes installation very easy and econo(symmetrical load) or, on the other hand,
sional evaluation and visualisation of the
in operation, they still feed in at 200 V.
They operate using two separate MPP
functions of the 10.0
Powador-protect
for grid
mical.
the regular configuration of a southTL3 | 12.0
TL3
inverter data.
This means that solar yields are optimum
trackers that can handle both symmeand plant protection and also| power mafacing roof without having to dispense
for comparatively small areas such as
trical and asymmetrical loads to allow
14.0
TL3
18.0
TL3
nagement in accordance with the GerIt is easy to achieve perfect communiwith the solar yield of a dormer (asymA number of country-specific default
dormers or carports but they also opefor optimum adjustment. Each tracker
man EEG 2012.
cation with these units. They are fitted
metrical load). The MPP trackers can
settings are programmed into the inverrate for more of the day. The peak efficiis able to process virtually all of the AC
with an integrated data logger with web
also be connected in parallel: installation
ters. These are easy to select during onency is 98 % and the European efficiency
output. This allows for all typical requiThe Powador 18.0 TL3 is available from
server, a graphical display for showing
costs less (you do not need an additional
site installation. The interface language
is also above average. The compact derements of complex designs to be fulfil98.0 % efficiency
July 2012.
operating data and a USB port for instalexternal disconnector) when strings need
can be selected separately. The inverters
sign weighing only 40 kg combined with
led; on the one hand, for example, full
ling firmware updates. The current softto be combined before the inverter. Two
conform to the German Medium and
the DC connection via solar connectors
configuration of an east/west-facing roof
Low Voltage Directives and support the
makes installation very easy and econo(symmetrical load) or, on the other hand,
Two MPP
symmetrical
functions
of thetrackers,
Powador-protect
for grid
mical.
the regular configuration of a southand asymmetrical
loading
possible
and plant
protection and
also power
mafacing roof without having to dispense
nagement in accordance with the GerIt is easy to achieve perfect communiwith the solar yield of a dormer (asymman EEG 2012.
cation with these units. They are fitted
metrical load). The MPP trackers can
with an integrated data logger with web
also be connected in parallel: installation
Multilingual menu
The Powador 18.0 TL3 is available from
server, a graphical display for showing
costs less (you do not need an additional
July 2012.
operating data and a USB port for instalexternal disconnector) when strings need
ling firmware updates. The current softto be combined before the inverter. Two
Photovoltaic systems of up to several
hundred kilowatts can be designed extremely flexibly in small, highly efficient
units with the transformerless threephase inverters Powador 10.0 TL3 to
18.0 TL3.
Graphical Display of efficiency
www.kaco-newenergy.de