Download Vastera VA-103 Installation manual

Transcript
1MRK 511 243-UEN -
Section 4
Section 4
IEC 60870-5-103 vendor specific implementation
IEC 60870-5-103 vendor specific
implementation
The signal and setting tables specify the information types supported by the IEDs
with the communication protocol IEC 60870-5-103 implemented.
The information types are supported when corresponding functions are included in
the protection and control IED.
4.1
Signals in monitoring direction
4.1.1
Measurands for IEC 60870-5-103 I103MEAS
4.1.1.1
Functionality
103MEAS is a function block that reports all valid measuring types depending on
connected signals.
The measurand reporting interval set for MMXU function blocks, using the
xDbRepInt and xAngDbRepInt settings, must be coordinated with the event
reporting interval set for the IEC 60870-5-103 communication using setting
CycMeasRepTime.
650 series
Communication Protocol Manual
25