1MRK 511 243-UEN - Section 4 Section 4 IEC 60870-5-103 vendor specific implementation IEC 60870-5-103 vendor specific implementation The signal and setting tables specify the information types supported by the IEDs with the communication protocol IEC 60870-5-103 implemented. The information types are supported when corresponding functions are included in the protection and control IED. 4.1 Signals in monitoring direction 4.1.1 Measurands for IEC 60870-5-103 I103MEAS 4.1.1.1 Functionality 103MEAS is a function block that reports all valid measuring types depending on connected signals. The measurand reporting interval set for MMXU function blocks, using the xDbRepInt and xAngDbRepInt settings, must be coordinated with the event reporting interval set for the IEC 60870-5-103 communication using setting CycMeasRepTime. 650 series Communication Protocol Manual 25