Download Craftsman 919.153090 Specifications
Transcript
TO DRAIN TANK 5. Place suitable container under unit to catch water. 6. Slightly tilt unit and turn drain valve counter-clockwise to open. Place unit back onto blocks to drain water from air tank. Risk of unsafe operation. Air tanks contain high pressure air. Keep face and other body parts away from outlet of drain. Use eye protection [ANSi Z87.1 (CAN/CSA Z94.3)] when draining as debris can be kicked up into face. Risk from noise. Use ear protection (ANSi S12.6 (S3.19) as air flow noise is loud when draining. NOTICE: Allow unit to cool before draining tank, drain valve becomes hot during operation. 1. Set the Off/Auto switch to "OFF". 2. Turn the regulator knob counterclockwise to set the outlet pressure to zero. 3. Pull and hold ring on safety valve allowing air to bleed from the tank until air pressure is minimized. 4. Place unit on blocks to lift unit off of ground. 7. Risk of Bursting. Water will condense in the air tank. if not drained, water will corrode and weaken the air tank causing a risk of air tank rupture. Risk of Property Damage. Drain water from air tank may contain oil and rust which can cause stains. 8. 16- ENG After the water has been drained, close the drain valve (clockwise). The air compressor can now be stored.