EZ-LINK SYSTEM
MANIFOLD INSTALLATION - EZ LINK CONNECTION
TWO CONTINUOUS FLOW WATER HEATERS - 862,864,866 SERIES 627 MODELS
no minimum
distance requirement
350
Temperature
Controller
(installed indoors)
(optional-627 models)
in use
priority
°C
x10
check
hot water
temperature
before use
water
volume
on
off
K
GPO x 2
Controller
Cable
Ez-Link
Cable
COLD WATER SUPPLY
HOT WATER
TO OUTLETS
GAS SUPPLY
PIPE SIZES:
Manifold DN25
Branches DN20
NOTE:
PRESSURE
LIMITING DEVICE
(PLV)
REQUIRED TO
TLD IF PLV
INSTALLED AT
WATER HEATER
NOTE: NON RETURN
VALVES (NRV)
REQUIRED ON COLD AND
HOT SUPPLY LINES TO A
TEMPERATURE LIMITING
DEVICE (TLD) IF NOT
INCORPORATED IN TLD.
TEMPERATURE LIMITING DEVICE
IF REQUIRED
SUITABLE FOR MAXIMUM FLOW.
COLD WATER
TEMPERED
WATER
TO
OUTLETS
SUPPLY
LEGEND
ISOLATION VALVE (FULL FLOW)
PRESSURE LIMITING VALVE
NON RETURN VALVE
TEMPERING
VALVE
Typical Two Unit Manifold with Ez-Link Connection
Indoor 362, 862, 864, 866 Series – 627 Models
Refer to the Owner‟s Guide and Installation Instructions supplied with the water
heater for additional information on the installation of the water heaters.
21