SIPB series 6-10 kVA 3:1 Phase or 1:1 Phase Model Capacity (VA/W) SIPB6KD SIPB10KD 6KVA/5.4KW 10KVA/9KW 3 phase 4 wires and Ground or Single Phase & Ground Phase Rated Voltage 380/400/415Vac or 220/230/240VAC Voltage Range 208~478Vac or 120VAC-276VAC 40Hz-70Hz Frequency Range Input Power Factor t0.99 Current THDi d5% (100% nonlinear load) Max.voltage: +15% (optional +5%, +10%, +25% ) Min. voltage: -45% (optional -20%, -30%) Frequency protection range: ±10% Bypass Voltage Range same as the bypass ECO Range Support Generator Input Single phase & Ground Phase 220/230/240VAC Rated Voltage Output Power Factor 0.9 Voltage Regulation ±2% Frequency Utility Mode ±1%, ±2%, ±4%, ±5%, ±10% of the rated frequency (optional) Battery Mode (50±0.2)Hz 3:1 Crest Factor d2% with linear load; d5% with non linear load THD Pure Sinewave Waveform ECO modet97%; Normal modet90% Efficiency Standard: 192Vdc; Optional Voltage: 216/240Vdc Voltage Full loadt2min (Standard), Long time unit depends on the capacity of external batteries Estimated remaining time displayed on the LCD Backup Time Battery 8~10 hours (Standard) Recharge time to 90% Maximum Current 6A; charge current can be set according to battery capacity installed. Charging Current Hardwire Battery Socket Utility to Battery : 0ms; Utility to bypass: 0ms Transfer Time Overload AC Mode Loadd110%: last 3min, d125%: last 30S, d150%: last 1S, t150% shut down UPS immediately. Bat. Mode Loadd110%: last 30S, d125%: last 1S, d150%: last 200ms, t150% shut down UPS immediately. Bypass Mode 40A (Input Breaker) Protection Overheat Line Mode: Switch to Bypass; Backup Mode: Shut down UPS immediately Alarm and Switch off Battery Low Upon Power On and Software Control Self-diagnostics Shut down UPS immediately EPO (optional) Advanced Battery Management Battery Complies with EN62040-2 Noise Suppression Alarms Line Failure, Battery Low, Overload, System Fault Audible & Visual Status LED & LCD Display Reading On the LCD Line Mode, Backup Mode, Eco Mode, Bypass Mode, Battery Low, Battery Bad, Overload & UPS Fault Input Voltage, Input Frequency, Output Voltage, Output Frequency, Load Percentage, Battery Voltage, Inner Temperature & Remaining Battery Backup Time 443×131 (3U) ×580 Dimension (W×H×D)mm Weight (Kg) Physical 25 Hardwire Output Connection Hardwire Comunication Interface Operating Temperature Storage Temperature Humidity Altitude Industry Standard 23 Input Connection External Battery Connection Environment 60A (Input Breaker) Hold Whole System Short Circuit Hardwire USB, RS485, Parallel Port, SNMPcard (optional) ,Centralized monitoring card (optional) 0...40°С -25...55°С 0 ~ 95% non condensing < 1500m CE, EN/IEC 62040-2, EN/IEC 62040-1-1, GOST R 21