Download AC UPS

Transcript
SIPB series 6-10 kVA 3:1 Phase or 1:1 Phase
Model
Capacity (VA/W)
SIPB6KD
SIPB10KD
6KVA/5.4KW
10KVA/9KW
3 phase 4 wires and Ground or Single Phase & Ground
Phase
Rated Voltage
380/400/415Vac or 220/230/240VAC
Voltage Range
208~478Vac or 120VAC-276VAC
40Hz-70Hz
Frequency Range
Input
Power Factor
t0.99
Current THDi
d5% (100% nonlinear load)
Max.voltage: +15% (optional +5%, +10%, +25% )
Min. voltage: -45% (optional -20%, -30%)
Frequency protection range: ±10%
Bypass Voltage Range
same as the bypass
ECO Range
Support
Generator Input
Single phase & Ground
Phase
220/230/240VAC
Rated Voltage
Output
Power Factor
0.9
Voltage Regulation
±2%
Frequency
Utility Mode
±1%, ±2%, ±4%, ±5%, ±10% of the rated frequency (optional)
Battery Mode
(50±0.2)Hz
3:1
Crest Factor
d2% with linear load; d5% with non linear load
THD
Pure Sinewave
Waveform
ECO modet97%; Normal modet90%
Efficiency
Standard: 192Vdc; Optional Voltage: 216/240Vdc
Voltage
Full loadt2min (Standard), Long time unit depends on the capacity of external batteries
Estimated remaining time displayed on the LCD
Backup Time
Battery
8~10 hours (Standard)
Recharge time to 90%
Maximum Current 6A; charge current can be set according to battery capacity installed.
Charging Current
Hardwire
Battery Socket
Utility to Battery : 0ms; Utility to bypass: 0ms
Transfer Time
Overload
AC Mode
Loadd110%: last 3min, d125%: last 30S, d150%: last 1S, t150% shut down UPS immediately.
Bat. Mode
Loadd110%: last 30S, d125%: last 1S, d150%: last 200ms, t150% shut down UPS immediately.
Bypass Mode
40A (Input Breaker)
Protection
Overheat
Line Mode: Switch to Bypass; Backup Mode: Shut down UPS immediately
Alarm and Switch off
Battery Low
Upon Power On and Software Control
Self-diagnostics
Shut down UPS immediately
EPO (optional)
Advanced Battery Management
Battery
Complies with EN62040-2
Noise Suppression
Alarms
Line Failure, Battery Low, Overload, System Fault
Audible & Visual
Status LED & LCD
Display
Reading On the LCD
Line Mode, Backup Mode, Eco Mode, Bypass Mode, Battery Low, Battery Bad, Overload & UPS Fault
Input Voltage, Input Frequency, Output Voltage, Output Frequency, Load Percentage, Battery Voltage, Inner
Temperature & Remaining Battery Backup Time
443×131 (3U) ×580
Dimension (W×H×D)mm
Weight (Kg)
Physical
25
Hardwire
Output Connection
Hardwire
Comunication Interface
Operating Temperature
Storage Temperature
Humidity
Altitude
Industry Standard
23
Input Connection
External Battery Connection
Environment
60A (Input Breaker)
Hold Whole System
Short Circuit
Hardwire
USB, RS485, Parallel Port, SNMPcard (optional) ,Centralized monitoring card (optional)
0...40°С
-25...55°С
0 ~ 95% non condensing
< 1500m
CE, EN/IEC 62040-2, EN/IEC 62040-1-1, GOST R
21