Download Lucent Technologies Release 8.2 Server User Manual

Transcript
3
Configuration 2: R7r (+CMS) <—ethernet—> R7csi
C-LAN Administration
Switch 2 Task— Assign Processor Channels
This task associates data links (hardware) with processor channels (software) on
Switch 2.
Steps
Begin
> Open the Processor Channel Assignment form — enter ch com p
change communications-interface processor-channels
Page 1 of X
PROCESSOR CHANNEL ASSIGNMENT
Proc
Chan Enable Appl.
mis____
1:
y
_______
2:
n
_______
3:
n
_______
4:
n
:
dcs ___
21:
y
:
_______
64:
n
Gtwy
To Mode
s
_
_
_
Interface
Destination
Session
Link/Chan
Node
Port Local/Remote
5_ 5001__ node-2____ 0____ 1 _
1__
__ _____ __________ 0____ ___
___
__ _____ __________ 0____ ___
___
__ _____ __________ 0____ ___
___
Mach
ID
__
__
__
__
c
5_
0
node-1____
5003_
21_
12_
1_
_
__
_____
__________
0____
___
___
__
> Enter values
Field
Conditions/Comments
Processor Channel 1: (connection to CMS)
Enable
Set to y.
Appl.
Enter mis for the CMS connection on Processor Channel 1.
Mode
Set the Mode to s (“server”) on both switches for connections
to CMS.
Interface Link
This must match the link number assigned on the node-5 data
module screen on this switch.
Interface Chan
For TCP/IP, interface channel numbers are in the range 5000
– 64500.
The recommended values are: 5001 for CMS, 5002 for Intuity
AUDIX, and 5003 for DCS connections that are not gateways.
These three values should be reused for multiple instances of
these applications; for example, if there are two Intuity
AUDIX’s, use 5002 for both; or if there are four DEFINITY
ECS’s, use 5003 for all four. The combination of Link,
Interface Channel, and Mach ID must be unique.
The recommended values for gateway switches is 6001–6099.
The interface channel number must be unique for each
gateway.
1 of 3
90
CID: 77730
Administration for Network Connectivity