Download HP ProLiant DL1000 Multi Node Server

Transcript
QuickSpecs
HP ProLiant DL1000 Multi Node Server
Power Specifications
Operational Input
Voltage Range (Vrms)
Frequency Range
(Nominal) (Hz)
Nominal Input Voltage
(Vrms)
Max Rated Output
Wattage Rating
Nominal Input Current (A
rms)
Max Rated Input Wattage
Rating (Watts)
Max. Rated VA
(Volt-Amp)
Efficiency (%)
Power Factor
Leakage Current (mA)
Maximum Inrush Current
(A peak)
Maximum Inrush Current
Duration (mS)
90Vac to 264Vac full range
47 Hz to 63 Hz
100
115
200
220
230
240
653.10
653.19
653.08
652.96
653.08
652.96
8.55
7.31
4.12
3.77
3.6
3.46
855
840.72
824.12
827.5
806.3
805.71
990
990
990
990
990
990
76.39
0.998
<3.5mA
60A
77.69
0.997
<3.5mA
60A
79.25
0.983
<3.5mA
60A
78.91
0.976
<3.5mA
60A
81
0.973
<3.5mA
60A
81.04
0.969
<3.5mA
60A
1mS
1mS
1mS
1mS
1mS
1mS
To review typical system power ratings use the Active Answers HP Power Advisor which is available via the online tool located at
URL: www.hp.com/go/proliant-energy-efficient or www.hp.com/go/hppoweradvisor
To drill down to calculators:
- Click on: "ProLiant Servers"
- Click on the Server of interest. Example: HP ProLiant DL1000 G6
- Click on: "Power Calculator" link. (You may need to scroll down to see it)
DA - 13309
North America — Version 12 — September 30, 2009
Page 40