Download CONTROL DATA®
Transcript
C C C 5. Check for 0. 005 to 0. 010 clearance between actuator arm and stop pin. Adjust by loosening two screws in switch adjustment bracket and rotating switch as necessary. 6. Replace right side panel. 7. Push power supply in cabinet and close front door. C Removal and Replacement (Figure 6-10) 1. Open cabinet front door and slide power supply out. 2. Remove right side panel. 3. Disconnect switch wires (at connector P322, Series Code 12 and above). 4. Remove two screws, washers, and the switch. 5. Install replacement switch, screws, and washers. 6. Reconnect wires to switch (at connector P322, Series Code 12 and above). 7. Adjust switch (see Check and Adjustment procedure). 8. Install right side panel. 9. Push power supply in and close front door. C” GROUND SPRING CHECK AND ADJUSTMENT 1. Open cabinet front door and slide power supply out. 2. Open rear door and swing logic chassis out. 3. Insert a non-metallic feeler gage (0. 005 inch) between ground spring and spindle C) C) shaft. 4. C Hook a push-pull gage (12210797) to extreme free end of ground spring. NOTE Multimeter provides most accurate indication of physical separation. 5. Force (applied perpendicular to spring) required to release and allow feeler gage to fall should be between 3. 53 and 5. 30 ounces. 6. If requirement is not met, loosen mounting block and reposition it slightly. Tighten screw securing mounting block and repeat steps 3 through 5. 6-30 70614600 J C C