Download Installation and Operating Instructions

Transcript
2
GALAXY
Pressure Relief
Valve
3/4"
1/2" Vent
Tapping
Alternate 1-1/2"
return (except
GG-75 thru
GG-175
FRONT VIEW
All GG and GXH
RIGHT SIDE
GG / GXH-PT
RIGHT SIDE
GXH-PZT-PPZT
RIGHT SIDE
GXH-PZ
GG SERIES HOT WATER BOILERS—DIMENSIONS IN MM FOLLOWED BY INCHES
A
B
C
D
E
F
G
H
J
K
GG-75H
502 193/4
335 133/16
127 5
1178 463/8
171 63/4
203 8
11/4
11/2
70 23/4
235 91/4
GG-100H
502 193/4
335 133/16
152 6
1353 531/4
330 13
203 8
11/4
11/2
70 23/4
235 91/4
GG-125H
502 193/4
335 133/16
152 6
1353 531/4
330 13
203 8
11/4
11/2
70 23/4
235 91/4
GG-150H
584 23
421 169/16
152 6
1353 531/4
330 13
248 93/4
11/4
11/2
70 23/4
235 91/4
GG-175H
584 23
421 169/16
152 6
1353 531/4
330 13
248 93/4
11/4
11/2
70 23/4
235 91/4
GG-200H
673 261/2
506 1915/16
178 7
1461 571/2
406 16
286 111/4
11/4
11/2
70 23/4
235 91/4
GG-225H
673 261/2
506 1915/16
178 7
1461 571/2
406 16
286 111/4
11/4
11/2
70 23/4
235 91/4
GG-250H
756 293/4
592 235/16
203 8
1514 595/8
432 17
330 13
11/4
11/2
70 23/4
235 91/4
GG-275H
756 293/4
592 235/16
203 8
1514 595/8
432 17
330 13
11/4
11/2
70 23/4
235 91/4
GG-300
845 331/4
662 261/16
203 8
1514 595/8
432 17
375 143/4
11/4
11/2
70 23/4
235 91/4
GG-325
845 331/4
662 261/16
203 8
1680 661/8
432 17
375 143/4
11/4
11/2
70 23/4
235 91/4
GG-350
927 361/2
764 301/16
229 9
1680 661/8
572 221/2
413 161/4
11/4
11/2
70 23/4
235 91/4
GG-350H
927 361/2
764 301/16
229 9
1680 661/8
572 221/2
413 161/4
11/4
11/2
70 23/4
235 91/4
GG-375
GG-375H
927 361/2 927 361/2
764 301/16 764 301/16
229 9
254 10
1680 661/8 1680 661/8
1
381 22 /2 381 221/2
413 161/4 413 161/4
11/4
11/4
11/2
11/2
70 23/4
70 23/4
235 91/4 235 91/4
GG-399H
927 361/2
764 301/16
254 10
1680 661/8
457 221/2
413 161/4
11/4
11/2
70 23/4
235 91/4
GXH SERIES STEAM AND HOT WATER BOILERS - DIMENSIONS IN MM FOLLOWED BY INCHES
GXHA-100 GXH-105 GXHA-120 GXH-125 GXH-150 GXHA-160 GXH-170 GXH-190 GXHA-200 GXH-210 GXH-230
A
B
C
D
E
F
G
H
J
K
L
M
584 23
419 161/2 421 169/16 419 161/2
127 5
127 5
127 5
1178 463/8
171 63/4
248 93/4 254 10
254 10
11/4
21/2
89 31/2
248 93/4
1
/2
727 28 5/8
727 28 5/8
584 23
421 169/16
152 6
1353 531/4
330 13
248 93/4
11/4
21/2
89 31/2
248 93/4
1
/2
673 261/2
673 261/2
506 1915/16 508 20 506 1915/16
152 6 178 7
178 7
1410 551/2
1410 551/2
356 14
356 14
286 111/4 298 11 3/4 286 111/4
11/4
11/4
21/2
21/2
89 31/2
89 31/2
248 93/4
248 93/4
1
1
/2
/2
727 28 5/8
673 261/2
756
506 1915/16 591 23 1/4 592
178 7 178
178 7
1410 551/2
1410
356 14
356
1
1
286 11 /4 343 13 /2 286
11/4
21/2
89 31/2
89
248 93/4
248
1
/2
727 28 5/8
293/4 756
239/16 592
7 178
551/2 1410
14 356
111/4 330
11/4
21/2
31/2 89
93/4 248
3
/4
273 mm
(103/4")
152 – 327 mm (6 – 12-7/8")
832 mm
(323/4")
337 mm
(131/4")
622 mm
(241/2")
321/2 826
261/16 662
178
7
551/2 1410
356
14
143/4 375
11/4
21/2
31/2 89
93/4 248
3
/4
321/2 826
261/16 662
203
7
551/2 1718
635
14
143/4 375
11/4
21/2
31/2 89
93/4 248
3
/4
Tankless Heater
Connections "L"
GXH-PT only
Install Manual ShutOff Valve
1524 mm (5
ft.) Above
When
Required
By Local
Code
318 mm
(121/2")
321/2
261/16
8
675/8
25
143/4
11/4
21/2
31/2
93/4
3
/4
826 321/2
662 261/16
229 9
1502 591/8
381 15
375 143/4
11/4
21/2
89 31/2
248 93/4
3
/4
Field Control (Effikal) Vent Damper
C
127mm
(5")
152mm
(6")
178mm
(7")
203mm
(8")
228mm
(9")
254mm
(10")
Tankless Heater
Connections "L"
except GXH-PZ
318
mm
(121/2")
1-1/4"
70 mm
(23/4")
Tapping on
Steam Boilers
70
mm
(23/4")
Return Tapping G on
right side of
boiler
57
mm
(21/4")
419 mm
(161/2")
673 mm
(261/2")
76
mm
(3")
660
mm
(26")
660
mm
(26")
648 mm
(251/2")
419 mm
(161/2")
184
mm
1
(7 /4")
184 mm
(21/4")
57 mm
(21/4")
LEFT SIDE
All GG and GXH
GXH-250 GXH-275 GXH-300 GXH-300H
293/4 826
239/16 662
7
178
551/2 1410
14
356
13
375
11/4
21/2
31/2 89
93/4 248
3
/4
ORIFICE SIZES indicated for Sea Level are factory installed in boiler unless otherwise specified by the local authority.
See page 15 for burner adjustment.
GAS VALVE CONNECTION Size is 1/2" f.p.t. for all sizes up to and including GG125 and GXH-125 depending upon configuration (natural, L.P., IID). Larger boilers,
gas valves are 3/4".
COMBUSTIBLE FLOOR KIT increases all height dimensions by 51 mm (2").
RAISED SLAB—When mounting boiler on a raised slab, the slab must extend at
least 51 mm (2") beyond the boiler cabinet on all sides.
CHIMNEY HEIGHT: 4.5 m (15 ft.) minimum from draft hood skirt to top of chimney.
CHIMNEY INSIDE DIAMETER must be same as Dimension “C” or larger. Larger
diameter and/or height may be required if two or more boilers or a boiler and
another appliance are vented to a single chimney.
RIGHT SIDE
GXH--PZ-PZT-PPZT
RIGHT SIDE
GG / GXH-PT
FRONT VIEW
All GG and GXH
ORIFICE SIZES AT HIGH ALTITUDES
BOILER MODEL
GG
Except GG-399H
GG-399H
GXH-105
through 275
GXH-300
GXH-300H
GG-350H
GAS TYPE
Natural
Propane
Natural
Propane
Natural
Propane
Natural
Propane
Natural
Gas*
*For L.P. Propane gas, consult factory.
Orifice Size for
Sea Level
42
54
40
53
44
54
43
55
43
610 to 1219 m
1219 to 1372 m
(2000 to 4000 ft.) (4000 to 4500 ft.)
43
55
42
54
43
55
44
54
44
43
55
42
54
45
55
44
56
44
H
I
152mm 122mm
(6")
(4-13/16")
165mm 135mm
(6-1/2") (5-5/16")
179mm 149mm
(7-1/16") (5-7/8")
205mm 175mm
(8-1/16") (6-7/8")
276mm 225mm
(10-7/8") (8-7/8")
327mm 276mm
(12-7/8") (10-7/8")