Download GALAXY

Transcript
GALAXY
25
WIRING DIAGRAMS FOR HOT WATER BOILERS WITH
INPUT UNDER 300,000 BTU/HR MODELS WITH IID
(INTERMITTENT IGNITION SYSTEM)
AND VENT DAMPER
WIRING DIAGRAMS FOR HOT WATER BOILERS
WITH INPUT OF 300,000 BTU/HR OR GREATER
MODELS WITH IID (INTERMITTENT IGNITION SYSTEM)
AND OPTIONAL VENT DAMPER
CAUTION: Label all wires prior to disconnection when servicing control.
Wiring errors can cause improper and dangerous operation. “Verify proper operation after servicing.”
HOT WATER (S) BOILER WITH 24V HONEYWELL
INTERMITTENT IGNITION, VENT DAMPER AND
HI-LIMIT CONTROL-CONSTANT CIRCULATION
BOILERS UNDER 300,000 BTU/HR INPUT
WARNING:
BOILERS WITH INPUT OF 300,000 BTU/HR OR GREATER
WARNING:
BLOCKED VENT SAFETY SWITCH MUST BE MOUNTED TO DRAFT HOOD BEFORE
OPERATING THE BOILER (SEE INSTRUCTION MANUAL GALAXY GG-400)
BEFORE INSTALLING VENT DAMPER , READ WARNING LABEL ON THIS
BOILER AND VENT DAMPER. READ SLANT/FIN VENT DAMPER
INSTALLATION INSTRUCTIONS.
FOR PROPANE USE S8600M OR S8670E, FOR NATURAL GAS S8600F,
S8600M OR S8670E.
SLANT/FIN VENT
DAMPER
1
4
HOT WATER (S) BOILER WITH 24V HONEYWELL
INTERMITTENT IGNITION, OPTIONAL VENT DAMPER AND
HI-LIMIT CONTROL-CONSTANT CIRCULATION
BLOCKED VENT SAFETY SWITCH MUST BE MOUNTED TO DRAFT HOOD BEFORE
OPERATING THE BOILER (SEE INSTRUCTION MANUAL GG-40).
BEFORE INSTALLING OPTIONAL VENT DAMPER , READ WARNING
LABEL ON THIS BOILER AND VENT DAMPER. READ SLANT/FIN VENT
DAMPER INSTALLATION INSTRUCTIONS.
FOR PROPANE USE S8600M OR S8670E ONLY, FOR NATURAL GAS S8600F,
S8600M OR S8670E.
OPTIONAL VENT DAMPER
3
FLEX METALLIC CONDUIT
3
2
BLUE
MV
S8600 OR S8670
2
ROLL-OUT
SWITCH
EMERGENCY
SWITCH
RED
P
MV/PV
24V
P
RED
RED
P
MV/PV
24V
BLOCKED VENT
SAFETY
SWITCH
24V THERMOSTAT
OR
CONTROLER
PV
MV
24V(GND)
HOT BLK.
H
RED
ROLL-OUT AND
BLOCKED VENT
SAFETY
SWITCHES
RED
1
24V(GND)
HOT BLK.
24V THERMOSTAT
OR
CONTROLER
MALE PLUG
4
VIOLET
24V
120V
S8600 OR S8670
P
RECEPTACLE A
4
3
YELLOW
VIOLET
WHT/YEL
BLUE
RED
YELLOW
WHITE NEUTRAL
N
VIOLET
EMERGENCY
SWITCH
4
3
2
1
RECEPTACLE B(CONNECTS TO
MALE PLUG ON ADAPTER
HARNESS)
1
H
2
1
VENT DAMPER
HARNESS SUPPLIED
WITH VENT DAMPER
MALE PLUG
4
24V
120V
2
WHITE
3
BLACK
RECEPTACLE B(CONNECTS TO
MALE PLUG ON ADAPTER
HARNESS)
4
FLEX METALLIC CONDUIT
3
1
VENT DAMPER
HARNESS SUPPLIED
WITH VENT DAMPER
BLK/YEL
2
VIOLET
NEUTRAL WHITE
3
1
4
WHITE
2
1
N
WHT/YEL
BLK/YEL
BLACK
1
RED
SLANT/FIN VENT
DAMPER
2
PV
SPARK
SPARK
GND
(BURNER)
GND
(BURNER)
250∞C
250∞C
ELECTRIC
IGNITION
PILOT
P
IGNITION
CABLE
ELECTRIC
IGNITION
PILOT
P
GREEN
HIGH LIMIT
GREEN
HIGH LIMIT
IGNITION
CABLE
BLACK
BLACK
PV
GND
PV
GND
GAS VALVE
GAS VALVE
PILOT GAS
LINE
VOLTAGE
1
MV
PILOT GAS
LINE
VOLTAGE
1
MV/PV
WHITE
MV
MV/PV
WHITE
RED
RED
CIRCULATOR FOR
HOT WATER BOILER
CIRCULATOR FOR
HOT WATER BOILER
NEUTRAL
WHITE
HOT
BLK
NEUTRAL
WHITE
HOT
BLK
1
2
1
EMERGENCY
SWITCH
EMERGENCY
SWITCH
120V
120V
L1
L1
L2
L2
24V
24V
GAS VALVE
GAS VALVE
MAIN
VALVE
COIL
THERMOSTAT
OR
CORONTROLER
PILOT
VALVE
GND COIL
MAIN
VALVE
COIL
MV
THERMOSTAT
OR
CONTROLER
MV
PV
PILOT
VALVE
GND COIL
PV
MV
MV
PV
PV
GND PV
GND PV
S8600
OR S8670
PILOT
LIGHTER
4
HIGH LIMIT
24V
MV MV
PV
S8600
OR S8670
PILOT
LIGHTER
(GND)
24V
4
3
SLANT/FIN
VENT DAMPER
ROLL-OUT AND BLOCKED
VENT SAFETY SWITCHES
HIGH LIMIT
WIRE LEGEND
FACTORY WIRED
FIELD CONNECTED
FACTORY SUPPLIED
FIELD CONNECTED
FIELD SUPPLIED
4
1
3
PLUG
2
WIRE LEGEND
FACTORY WIRED
FIELD CONNECTED
FACTORY SUPPLIED
FIELD CONNECTED
FIELD SUPPLIED
4
WIRE ENTRANCE
ENDS POLARIZED
1
3 CONNECTORS
RECEPTACLE
PROVIDE DISCONNECT MEANS & OVERLOAD PROTECTION
1
AS REQUIRED.
IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE
APPLIANCE MUST BE REPLACED, IT MUST BE REPLACED WITH
TYPE 105˚ C OR ITS EQUIVALENT.
IF THE WIRES MARKED ( P ) MUST BE REPLACED,THEY MUST BE
REPLACED WITH POWER LIMITED FIRE PROTECTIVE CABLE.
GALAXY
(GND)
24V
3
SLANT/FIN
VENT DAMPER
ROLL-OUT AND BLOCKED
VENT SAFETY SWITCHES
1
2
1
2
MV MV
PV
TERMINALS MARKING SHOWN
ARE FOR BOILER HARNESS
MALE PLUG.
TERMINALS MARKING SHOWN
ARE FOR BOILER HARNESS
MALE PLUG.
2
24V
41-1531
4
2
1
3
PLUG
2
4
WIRE ENTRANCE
ENDS POLARIZED
3 CONNECTORS
RECEPTACLE
1
PROVIDE DISCONNECT MEANS & OVERLOAD PROTECTION
AS REQUIRED.
FOR FIELD-WIRED CONNECTIONS, USE WIRING
MATERIAL RATED FOR AT LEAST 75˚C.
IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE
APPLIANCE MUST BE REPLACED, IT MUST BE REPLACED WITH
TYPE 105˚ C OR ITS EQUIVALENT.
IF THE WIRES MARKED( ) MUST BE REPLACED,THEY MUST BE
REPLACED WITH POWER LIMITED FIRE PROTECTIVE CABLE.
1
2
GALAXY
41-1532