Download GALAXY
Transcript
GALAXY 25 WIRING DIAGRAMS FOR HOT WATER BOILERS WITH INPUT UNDER 300,000 BTU/HR MODELS WITH IID (INTERMITTENT IGNITION SYSTEM) AND VENT DAMPER WIRING DIAGRAMS FOR HOT WATER BOILERS WITH INPUT OF 300,000 BTU/HR OR GREATER MODELS WITH IID (INTERMITTENT IGNITION SYSTEM) AND OPTIONAL VENT DAMPER CAUTION: Label all wires prior to disconnection when servicing control. Wiring errors can cause improper and dangerous operation. “Verify proper operation after servicing.” HOT WATER (S) BOILER WITH 24V HONEYWELL INTERMITTENT IGNITION, VENT DAMPER AND HI-LIMIT CONTROL-CONSTANT CIRCULATION BOILERS UNDER 300,000 BTU/HR INPUT WARNING: BOILERS WITH INPUT OF 300,000 BTU/HR OR GREATER WARNING: BLOCKED VENT SAFETY SWITCH MUST BE MOUNTED TO DRAFT HOOD BEFORE OPERATING THE BOILER (SEE INSTRUCTION MANUAL GALAXY GG-400) BEFORE INSTALLING VENT DAMPER , READ WARNING LABEL ON THIS BOILER AND VENT DAMPER. READ SLANT/FIN VENT DAMPER INSTALLATION INSTRUCTIONS. FOR PROPANE USE S8600M OR S8670E, FOR NATURAL GAS S8600F, S8600M OR S8670E. SLANT/FIN VENT DAMPER 1 4 HOT WATER (S) BOILER WITH 24V HONEYWELL INTERMITTENT IGNITION, OPTIONAL VENT DAMPER AND HI-LIMIT CONTROL-CONSTANT CIRCULATION BLOCKED VENT SAFETY SWITCH MUST BE MOUNTED TO DRAFT HOOD BEFORE OPERATING THE BOILER (SEE INSTRUCTION MANUAL GG-40). BEFORE INSTALLING OPTIONAL VENT DAMPER , READ WARNING LABEL ON THIS BOILER AND VENT DAMPER. READ SLANT/FIN VENT DAMPER INSTALLATION INSTRUCTIONS. FOR PROPANE USE S8600M OR S8670E ONLY, FOR NATURAL GAS S8600F, S8600M OR S8670E. OPTIONAL VENT DAMPER 3 FLEX METALLIC CONDUIT 3 2 BLUE MV S8600 OR S8670 2 ROLL-OUT SWITCH EMERGENCY SWITCH RED P MV/PV 24V P RED RED P MV/PV 24V BLOCKED VENT SAFETY SWITCH 24V THERMOSTAT OR CONTROLER PV MV 24V(GND) HOT BLK. H RED ROLL-OUT AND BLOCKED VENT SAFETY SWITCHES RED 1 24V(GND) HOT BLK. 24V THERMOSTAT OR CONTROLER MALE PLUG 4 VIOLET 24V 120V S8600 OR S8670 P RECEPTACLE A 4 3 YELLOW VIOLET WHT/YEL BLUE RED YELLOW WHITE NEUTRAL N VIOLET EMERGENCY SWITCH 4 3 2 1 RECEPTACLE B(CONNECTS TO MALE PLUG ON ADAPTER HARNESS) 1 H 2 1 VENT DAMPER HARNESS SUPPLIED WITH VENT DAMPER MALE PLUG 4 24V 120V 2 WHITE 3 BLACK RECEPTACLE B(CONNECTS TO MALE PLUG ON ADAPTER HARNESS) 4 FLEX METALLIC CONDUIT 3 1 VENT DAMPER HARNESS SUPPLIED WITH VENT DAMPER BLK/YEL 2 VIOLET NEUTRAL WHITE 3 1 4 WHITE 2 1 N WHT/YEL BLK/YEL BLACK 1 RED SLANT/FIN VENT DAMPER 2 PV SPARK SPARK GND (BURNER) GND (BURNER) 250∞C 250∞C ELECTRIC IGNITION PILOT P IGNITION CABLE ELECTRIC IGNITION PILOT P GREEN HIGH LIMIT GREEN HIGH LIMIT IGNITION CABLE BLACK BLACK PV GND PV GND GAS VALVE GAS VALVE PILOT GAS LINE VOLTAGE 1 MV PILOT GAS LINE VOLTAGE 1 MV/PV WHITE MV MV/PV WHITE RED RED CIRCULATOR FOR HOT WATER BOILER CIRCULATOR FOR HOT WATER BOILER NEUTRAL WHITE HOT BLK NEUTRAL WHITE HOT BLK 1 2 1 EMERGENCY SWITCH EMERGENCY SWITCH 120V 120V L1 L1 L2 L2 24V 24V GAS VALVE GAS VALVE MAIN VALVE COIL THERMOSTAT OR CORONTROLER PILOT VALVE GND COIL MAIN VALVE COIL MV THERMOSTAT OR CONTROLER MV PV PILOT VALVE GND COIL PV MV MV PV PV GND PV GND PV S8600 OR S8670 PILOT LIGHTER 4 HIGH LIMIT 24V MV MV PV S8600 OR S8670 PILOT LIGHTER (GND) 24V 4 3 SLANT/FIN VENT DAMPER ROLL-OUT AND BLOCKED VENT SAFETY SWITCHES HIGH LIMIT WIRE LEGEND FACTORY WIRED FIELD CONNECTED FACTORY SUPPLIED FIELD CONNECTED FIELD SUPPLIED 4 1 3 PLUG 2 WIRE LEGEND FACTORY WIRED FIELD CONNECTED FACTORY SUPPLIED FIELD CONNECTED FIELD SUPPLIED 4 WIRE ENTRANCE ENDS POLARIZED 1 3 CONNECTORS RECEPTACLE PROVIDE DISCONNECT MEANS & OVERLOAD PROTECTION 1 AS REQUIRED. IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE APPLIANCE MUST BE REPLACED, IT MUST BE REPLACED WITH TYPE 105˚ C OR ITS EQUIVALENT. IF THE WIRES MARKED ( P ) MUST BE REPLACED,THEY MUST BE REPLACED WITH POWER LIMITED FIRE PROTECTIVE CABLE. GALAXY (GND) 24V 3 SLANT/FIN VENT DAMPER ROLL-OUT AND BLOCKED VENT SAFETY SWITCHES 1 2 1 2 MV MV PV TERMINALS MARKING SHOWN ARE FOR BOILER HARNESS MALE PLUG. TERMINALS MARKING SHOWN ARE FOR BOILER HARNESS MALE PLUG. 2 24V 41-1531 4 2 1 3 PLUG 2 4 WIRE ENTRANCE ENDS POLARIZED 3 CONNECTORS RECEPTACLE 1 PROVIDE DISCONNECT MEANS & OVERLOAD PROTECTION AS REQUIRED. FOR FIELD-WIRED CONNECTIONS, USE WIRING MATERIAL RATED FOR AT LEAST 75˚C. IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE APPLIANCE MUST BE REPLACED, IT MUST BE REPLACED WITH TYPE 105˚ C OR ITS EQUIVALENT. IF THE WIRES MARKED( ) MUST BE REPLACED,THEY MUST BE REPLACED WITH POWER LIMITED FIRE PROTECTIVE CABLE. 1 2 GALAXY 41-1532