Download Silverstone ST56F

Transcript
2. DC OUTPUT
2.1 DC voltage regulation
Parameter
+3.3V
+5V
+12V1
+12V2
-12V
+5VSB
Range
+/-5%
+/-5%
+/-5%
+/-5%
+/-10%
+/-5%
Min
+3.14
+4.75
+11.4
+11.4
-10.8
+4.75
Nom.
+3.3
+5
+12
+12
-12
+5
Max
+3.47
+5.25
+12.6
+12.6
-13.2
+5.25
Unit
Volts
Volts
Volts
Volts
Volts
Volts
2.2 Load ranges
2.2.1 : (560 Watts Load Ratings)
Parameter
+3.3V
+5V
+12V1
+12V2
-12V
+5VSB
Min
0.5
0.3
1.0
1.0
0.0
0.0
Nom.
12.0
24.0
17.0
15.0
0.5
2.0
Max
30.0
30.0
18.0
18.0
0.5
2.0
Peak
19.0
19.0
2.5
Notes:
(1) The maximum continuous total DC outputs power shall not exceed 560W
(2) The maximum peak total DC output power shall not exceed 570W
(limited to duty cycle of 1 minute on, 10 minutes off at 40°C ambient).
(3) The maximum continuous load on +5V and +3.3V outputs shall not exceed 180W.
(4) The maximum combined current for the +12V outputs shall be 36A
(5) When +5V load is 28A, +12V (+12V1 and +12V2) minimum load is 2A
(6) When the combined current for the +12V outputs is 29A, the +5V minimum load is 5A.
(7) When the combined current for the +12V outputs is 22A, the +5V minimum load is 2A.
2.3 Output Ripple
2.3.1 Ripple regulation
Parameter
Ripple&Noise
+3.3V
80
+5V
50
+12V1
120
+12V2
120
-12V
120
+5VSB
50
Unit
mVp-p
mVp-p
mVp-p
mVp-p
mVp-p
mVp-p
Unit
Amps
Amps
Amps
Amps
Amps
Amps