Download Velleman DVM93 multimeter

Transcript
DVM93
Rev. 01
0
Warning:
his device was
w designe
ed in accord
dance with EN 61010--1 installation categorry CAT II 60
00V. This
Th
im
mplies that certain
c
resttrictions in use apply that
t
are related to voltages and voltage pea
aks which
can occur witthin the env
vironment of use. Reffer to the ta
able above..
This de
evice is only suitable for
f measurements up
p to 600V in a CAT II
I environme
ent.
5.. Pollutio
on degre
ee
IEC
C 61010-1 specifies different
d
typ
pes of pollu
ution enviro
onments, fo
or which diffferent prottective
me
easures are
e necessary
y to ensure
e safety. Ha
arsher envirronments require
r
morre protectio
on, and the
pro
otection ag
gainst the pollution
p
wh
hich is to be
e found in a certain en
nvironmentt depends mainly
m
on the
t
ins
sulation and
d the enclo
osure prope
erties. The pollution de
egree rating of the DV
VM indicates in which
en
nvironment the device may be us
sed.
Po
ollution degree 1 No pollution
p
orr only dry, nonconduct
n
tive pollutio
on occurs. T
The pollutio
on has no
influ
uence (only to be foun
nd in herme
etically sealled enclosu
ures).
Po
ollution degree 2 Only
y noncondu
uctive polluttion occurs. Occasiona
ally, tempo
orary condu
uctivity
caus
sed by cond
densation is
s to be exp
pected (hom
me and offic
ce environm
ments fall
unde
er this cate
egory).
Po
ollution degree 3 Cond
ductive pollution occu
urs, or dry nonconduct
n
tive pollutio
on occurs th
hat become
es
cond
ductive due
e to conden
nsation thatt is to be ex
xpected (industrial environments
s
and environme
ents expose
ed to outsid
de air - but not in conttact with prrecipitation).
Po
ollution degree 4 The pollution generates
g
p
persistent
co
onductivity
y caused by
y conductive
e dust or by
rain or snow. (exposed ou
utdoor enviironments and
a
environ
nments where high
midity levels
s or high co
oncentration
ns of fine particles
p
occ
cur)
hum
Warning:
his device was
w designe
ed in accord
dance with EN 61010--1 pollutio
on degree 2. This imp
plies that
Th
certain restric
ctions in us
se apply tha
at are relatted to pollu
ution which can occur within the environment
of use. Refer to the tablle above.
o
suitable for me
easuremen
nts in Polllution degree class 2
This device is only
envirronments..
6.. Mainten
nance / battery and fuse
e replace
ement
WARN
NING: To av
void electrical shock always
a
rem
move the te
est leads prrior to open
ning case. To
T
preven
nt fire, insta
all fuses witth AMP/VOLT rating as shown.
Remarrk: refer to
o the warnin
ng on the back
b
of the meter
nternal partts yourself. Replace da
amaged or lost access
sories by id
dentical one
es
Do nott replace in
with th
he same spe
ecifications
s. Order spa
are accesso
ories e.g. te
est probes at your dea
aler.
Switch off the me
eter and rem
move test leads prior to replacing the batte
ery or fuses
s.
a. General maintenan
m
nce:
device regu
ularly with a moist, lint-free cloth
h. Do not use alcohol, solvents or abrasive
• Wipe the d
products.
b. Battery/ffuse replacement
• Replace th
he battery as
a soon as the “ ” ind
dication app
pears on th
he display. Low/bad ba
atteries can
n
produce fa
alse reading
gs. The fuse rarely needs to be replaced
r
an
nd a blown fuse is almost always
caused by a human error.
e
• Switch off the multi-m
meter.
• Remove te
est probes from the circuit underr test. Remove all testt leads from
m the inputt jacks.
he protectiv
ve cover an
nd release the
t
2 screw
ws at the ba
ack of the m
meter and gently
g
open
n
• Remove th
the housin
ng.
• Replace th
he battery (9V
(
6LF22). Do not use rechargeable batte
eries and in
nsert following the righ
ht
polarity.
• Replace th
he fuse: cerramic – hig
gh breaking capacity 6.3x32mm
6
1 x F500mA
A/600V & 1 x
F10A/250V
V
• Close the housing an
nd tighten the 2 screw
ws. Put the protective
p
c
cover
back.
7.. Front panel
p
Des
scription
n
Re
efer to the illustrations
i
s on page 2 of this ma
anual.
22.08.2011
5
©Velleman
n nv