DIP Switch / Mode Settings Appendix A: DIP Switch/Mode Settings Setting the DIP Switches on RS-232/422/485 Ports Set the DIP switches to configure the desired operating mode as follows: 422/485 Switch 1 232 Switch 2 TX On TX SD Switch 3 RX On RX SD RS-232 Mode 422/485 232 TX On TX SD RX On RX SD RS-422 Mode 422/485 232 TX On TX SD RX On RX SD 4-wire RS-485 Mode 422/485 232 TX On TX SD RX On RX SD 2-wire RS-485 Mode Figure 25. RS-232/422/485 DIP Switch Settings. DIP Switch 1 (RS-232/422/485 ports) The top DIP switch (1) configures the port for RS-232 or RS-422/485 operation. This switch is the only one that is required to be set for RS-232 operation. The positions of switches 2 and 3 do not matter when switch 1 is set for RS-232 operation. DIP Switch 2 (RS-232/422/485 ports) The middle DIP switch (2) configures the port for RS-485 or RS-422 operation. For RS422 operation (which uses two wire pairs and sends point-to-point or point-tomultipoints) the transmitter can be enabled all the time. Placing the middle DIP switch in the TX ON position accomplishes this. For RS-485 operation the middle DIP switch is placed in the TX SD position. In this position the transmitter is only enabled when data is being sent. The transmitter is triA-4 Appendix A Document Number 3PCI-4310m