Download Chief CMS492
Transcript
CMS491/492 Installation Instructions DISCLAIMER Milestone AV Technologies and its affiliated corporations and subsidiaries (collectively “Milestone”), intend to make this manual accurate and complete. However, Milestone makes no claim that the information contained herein covers all details, conditions or variations, nor does it provide for every possible contingency in connection with the installation or use of this product. The information contained in this document is subject to change without notice or obligation of any kind. Milestone makes no representation of warranty, expressed or implied, regarding the information contained herein. Milestone assumes no responsibility for accuracy, completeness or sufficiency of the information contained in this document. Chief® is a registered trademark of Milestone AV Technologies. All rights reserved. IMPORTANT SAFETY INSTRUCTIONS WARNING: A WARNING alerts you to the possibility of WARNING: Use this mounting system only for its intended use as described in these instructions. Do not use attachments not recommended by the manufacturer. WARNING: For indoor use only. WARNING: Never operate this mounting system if it is damaged. Return the mounting system to a service center for examination and repair. IMPORTANT ! : The CMS491/492 has been designed to be mounted recessed into a suspended ceiling secured by a WireVice system. IMPORTANT ! : The CMS491/492 has been designed to support a single electrical receptacle or a double receptacle. NOTE: Ambient Temperature - The manufacturer's maximum ambient temperature is 120°F (49°C) and minimum ambient temperature is 40°F (4°C) so that the installer is able to determine acceptability of use of accessories and components in the operating environment. serious injury or death if you do not follow the instructions. CAUTION: A CAUTION alerts you to the possibility of damage or destruction of equipment if you do not follow the corresponding instructions. follow all instructions can result in serious personal injury, damage to equipment, or voiding of factory warranty! It is the installer’s responsibility to make sure all components are properly assembled and installed using the instructions provided. NOTE: When selecting a Listed 120 Vac Receptacle for use as the main power source for the CMS Series boxes (to power the A/V equipment), make sure that AC Receptacle is rated at least 15A and it is used in the building's AC branch circuit that is connected to a circuit breaker rated at least 15A. Do not connect more than 12A from the 15A Receptacle, or 16A from the 20A Receptacle. WARNING: Failure to provide adequate structural strength In the U.S., the equipment shall be installed per the applicable requirements of the National Electrical Code, ANSI/NFPA 70. WARNING: Failure to read, thoroughly understand, and for this accessory can result in serious personal injury or damage to equipment! It is the installer’s responsibility to make sure the structure to which this accessory is attached can support five times the combined weight of all equipment. Reinforce the structure as required before installing the component. WARNING: Exceeding the weight capacity can result in serious personal injury or damage to equipment! It is the installer’s responsibility to make sure the combined weight of: • all components located in the complete accessory does not exceed 100 lbs (45 kg). • all components attached to the CMS491/CMS492 Series component shelf may not exceed 25 lbs (22 kg) per shelf; • all components attached to the extension column, (CMS491C/CMS492C models only) does not exceed 50 lbs (22 kg). 2 NOTE: Spacings - To ensure safe operation of the equipment installed in the enclosure, per National Electric Code, ANSI/NFPA 70 Article 725.136(D)(1), a minimum separation of 6mm (0.25 in.) between power cords and signal or communication cables must be maintained. In Canada, the equipment shall be installed per the applicable requirements of the Canadian Electrical Code, CSA C22.1. NOTE: The CMS491/492 Series consists of: • CMS491 1x2 Standard Ceiling Box • CMS491C 1x2 Ceiling Box with Column Drop • CMS492 2x2 Standard Ceiling Box • CMS492C 2x2 Ceiling Box with Column Drop NOTE: The CMS491C and CMS492C each accommodate a Listed Chief CMS Series extension column (not included). --SAVE THESE INSTRUCTIONS--