Download Emerson SR5 Data Sheet
Transcript
Bulletin 71.1:SR5 30 (2,1) Fisher Type SR5 Competitor 1 Competitor 2 Competitor 3 Outlet Pressure, psig (bar) 25 (1,7) Setpoint 10% Offset 20 (1,4) 15 (1,0) 10 (0,7) 5 (0,4) E0965 set flow Increasing Flow max flow Figure 4. Type SR5 Performance Comparison Features • Nonporous Polished Body and Internals for High Purity Processing—Body, plug, and diaphragm plate (when applicable) are machined from 316L Stainless Steel. All internal wetted surfaces are mechanically polished and electropolished to 20 µin (0.5 µm) Ra. • Wide Control Range—Typical set points range from 2 to 135 psig (0,2 to 9,3 bar) to cover a wide range of applications. • Easy Maintenance—The design incorporates a metal-to-metal stop to protect diaphragms from damage due to over-compression at outer circumference. Tri-clamp® allows easy access to internal parts. • Optional Diaphragm Support—A diaphragm support is added to the regulator for installations that will be exposed to vacuum conditions. • Large Turndown Ratio—No need for reduced Cv trims at low flows. • Diaphragm Cycle Life—Metal 316L Stainless Steel diaphragm is designed to maximize service life. • Self-Draining—Fluids will drain toward the inlet of the body when the regulator is installed with the spring case in the upright vertical position. • Covered Adjusting Screw—Electropolished stainless steel adjusting screw cover improves the aesthetics and cleanability of the regulator. • Clean in Place or Steam in Place—The lock in place pin can be inserted in the side of the spring case to prevent the valve plug from closing during cleaning. • Sanitary Design Standards—Designed to meet 3A®, ASME BPE, and European Hygienic Equipment Design Group criteria. • Tight Shutoff—Soft seat available to ensure better shutoff and prevent excess pressure buildup in deadend applications. • Highly Stable—The upper guide ring provides for stable control over entire operating range. • Optional T-Handle Available—T-Handle option available to accommodate frequent adjustments. • Remote Setpoint Capability—An optional spring case configuration permits pressure loading. Loading pressure varied from a remote location adjusts the setpoint in direct proportion. • Superior flow performance and accuracy—The Type SR5 is designed to deliver high flows with minimal offset to maintain an even pressure over the full range of flow.