Download Tecumseh AGA4560EXNXF Performance Data Sheet

Transcript
March 16, 2011
Specifications/ Parts:
Model
Unit Bill of Material
Nominal Volts-Hz-Ph
Refrigeration Range
Design Pressure Low
Design Pressure High
Voltage Range
Min. Circuit Ampacity
Max. Fuse Size (amps)
Compressor Model
Comp. Bill of Material
Compressor RLA/LRA
Overload
Relay
Run Capacitor
Run Capacitor Rating
Start Capacitor
Start Capacitor Rating
Contactor
Unit Drawing
Wiring Diagram
AGA4560EXNXF
2A5109-1
208-230-60-1
20° to 55°F
150
450
187 to 254
42.1
70
AGA5561EXN
AG133ET-018-P2
30.5 / 165.0
INTERNAL
820ARR3H46
85PR440E90
55MFD 440V(M)VDE
85PS330D16
130-156 MFD 330V VDE
91013
DGU1901-45
91263-03
Fan Motor
Fan Motor RLA
Fan Blade
Fan Guard
Fan Shroud
High Pressure Switch
Low Pressure Control
Oil Separator *
Condenser
Fan Switch
Fan Switch
Receiver Tank
Liquid Valve
Liquid Filter *
Sight Glass *
Suction Valve *
Rotolock Valve Gasket
Discharge Valve
Suction Filter *
Accumulator *
Crankcase Heater
Defrost Timer *
Suction Shut Off Valve*
Liquid Shut Off Valve*
Shrader Valve Body*
Valve Core*
* = Equipped Units Only
Electrical Diagram
810S186B40 (2)
1.9 Each
51528-3 (2)
70832 (2)
70611-1
84095-1
84026-2
704-00003
50777-6
84096-1
84096-2
51083
56596
70126-3
70084-2
31529-1
30233
56596
70082
TK00044000
90699
N/A
56500-K14
56500-K08
56510
56552