Download Tecumseh AGA4560EXNXF Performance Data Sheet
Transcript
March 16, 2011 Specifications/ Parts: Model Unit Bill of Material Nominal Volts-Hz-Ph Refrigeration Range Design Pressure Low Design Pressure High Voltage Range Min. Circuit Ampacity Max. Fuse Size (amps) Compressor Model Comp. Bill of Material Compressor RLA/LRA Overload Relay Run Capacitor Run Capacitor Rating Start Capacitor Start Capacitor Rating Contactor Unit Drawing Wiring Diagram AGA4560EXNXF 2A5109-1 208-230-60-1 20° to 55°F 150 450 187 to 254 42.1 70 AGA5561EXN AG133ET-018-P2 30.5 / 165.0 INTERNAL 820ARR3H46 85PR440E90 55MFD 440V(M)VDE 85PS330D16 130-156 MFD 330V VDE 91013 DGU1901-45 91263-03 Fan Motor Fan Motor RLA Fan Blade Fan Guard Fan Shroud High Pressure Switch Low Pressure Control Oil Separator * Condenser Fan Switch Fan Switch Receiver Tank Liquid Valve Liquid Filter * Sight Glass * Suction Valve * Rotolock Valve Gasket Discharge Valve Suction Filter * Accumulator * Crankcase Heater Defrost Timer * Suction Shut Off Valve* Liquid Shut Off Valve* Shrader Valve Body* Valve Core* * = Equipped Units Only Electrical Diagram 810S186B40 (2) 1.9 Each 51528-3 (2) 70832 (2) 70611-1 84095-1 84026-2 704-00003 50777-6 84096-1 84096-2 51083 56596 70126-3 70084-2 31529-1 30233 56596 70082 TK00044000 90699 N/A 56500-K14 56500-K08 56510 56552