Download Installation and operating instructions

Transcript
MODPARK Parking System
Manual Barriers
1.
Technical data AB 25- AB 40
Operative range
Application
- Parking area, parking garage
for ...
- Company entrance
- Safety area
- Toll-station
Drive pulse
- Push-button, card reader, key switch,
from ...
remote control, desk top panel etc.
- Handsfree data-capture
- Induction loop
Safety
- Reversing on obstacle
- Best protection against vandalism
- Ergonomic emergency release
Typical Data
Drawn power
Running time
Maximum boom length
Effective length
Reversing on obstacle
Boom weight /
Barrier weight
AB 25
0.37 kW
ca. 1.4 s
2500 mm
2280 mm
switchable
4 / 2 kg
47.5 kg
General Data
Mains supply
Max. current
Duty cycle
Degree of protection
Temperature range
Controller
Measurement (w/l/h)
Foundation (frost-proof)
Boom connector
Housing
Mechanical parts
AB 25 HS
0.37 kW
ca. 0.9 s
2500 mm
2280 mm
switchable
4 / 2 kg
47.5 kg
230V / 50Hz
2,5A
100%
IP 54
-20°C to +70°C
MO 63
350x300x1100 mm
550x500x800 mm
left or right
aluminium
steel, zinc coated
AB 30
0.25 kW
ca. 2.3 s
3000 mm
2780 mm
switchable
4.7 / 2.3 kg
47.5 kg
AB 40
0.26 kW
ca. 3.2 s
4000 mm
3780 mm
switchable
6 / 3 kg
50 kg
The accident prevention regulations and the approved safety rules have to be observed.
Moving parts inside the barrier can cause accidents.
Do not operate the barrier when housing is open.
Measurements AB 25 – AB 40
820
1100
1.1.
300
Boom length minus 360mm
Drilling template
barrier housing
203
800
273
247
179
550
Fixed support
500
320
130
Panel/Roadway
110
160
140
350
Foundation
500x550x800
2500/3000/4000
We reserve the right to make technical improvements without prior notice.
T:\Dokumentation\Modpark\Peripherie\Schranken\Englisch\AB25-80(MO63)-En2002V11.DOC