Proline Kryomats Command Explanation 0 = make-contact open/ 1 = make-contact closed. IN_DO_02 State of Contact output 2: 0 = make-contact open/ 1 = make-contact closed. IN_DO_03 State of Contact output 3: 0 = make-contact open/ 1 = make-contact closed. IN_MODE_00 Keys Master: 0 = free / 1 = inhibited. IN_MODE_01 Control: 0 = int. / 1 = ext. Pt100 / 2 = ext. Analogue / 3 = ext. Serial. IN_MODE_02 Standby: 0 = Unit ON / 1 = Unit OFF. IN_MODE_03 Keys Command: 0 = free / 1 = inhibited. IN_MODE_04 Setpoint offset source: 0=normal/1=ext.Pt/2=ext.analogue/3=ext.serial. TYPE Read equipment type. VERSION_R Read software type of control system. VERSION_S Read software type of protection system. VERSION_B Read software type of Command. VERSION_T Read software type of cooling system. VERSION_A Read software type of analogue module. VERSION_V Read software type of RS232/485 module. VERSION_D Read software type of digital module. VERSION_M_0 Read software type of solenoid valve (Cooling water). VERSION_M_1 Read software type of solenoid valve (Automatic refill). VERSION_M_2 Read software type of solenoid valve (Level controller). STATUS Read equipment status 0 = OK, -1 = error. STAT Read error diagnosis response: XXXXXXX → X = 0 no error, X = 1 error. 1 Char = error. 2 Char = Alarm. 3 Char = Warning. 4 Char = over temperature. 5 Char = low-level error. 6 Char = high-level error (at adjustment alarm). 7 Char = no external control variable. RMP_IN_00_XXX Read a program segment XXX (response: e. g. 030.00_010.00 set point temperature 30.00°C, time = 10 min, tolerance = 5.00°C, pump level = 1). RMP_IN_01 Read the current segment number. RMP_IN_02 Read the set number of program runs. RMP_IN_03 Read the current program run. RMP_IN_04 Read the program to which further instructions apply. RMP_IN_05 Read which program is running now (0=none). LOG_IN_00_XXXX Query a measuring point XXXX from data logger (Reply: e. g. 020.00_021.23_030.50 => set point temperature = 20.00°C, bath temperature = 21.23°C, external temperature = 30.5°C). LOG_IN_01 Query all measuring points from data logger As a difference to the command “LOG_IN_00”, a tabulator is used here as separator instead of ,_’ . The measuring points are separated by CR and LF. The end is marked by CR LF CR LF. LOG_IN_02 Query the start time from the data logger (Reply: e.g. 20_14_12_20 day 20, 14:12:20). LOG_IN_03 94 Query the acquisition interval from the data logger (Reply in seconds). Starting up YAUE0007 / 3/7/2013