76 77 78 79 80 81 Bios Flash 1 ACPI State IPMI Watchdog Health Error IPMB0 Link State FRU0 IPMBL State Discrete Bios Flash 1 Sensor type = 1Eh Boot Error Event Reading type code = 6Fh Sensor Specific Only offset 3 is used See IPMI v2.0 table 42-3, Sensor type code 1Eh for sensor definition Discrete Advance Configuration and Power Interface State Sensor type = 22h System ACPI Power State Event Reading type code = 6Fh Sensor specific Only offset 0,4,5,10,11,12,14 are used. See IPMI v2.0 table 42-3, Sensor type code 22h (ACPI Power State) for sensor definition Discrete IPMI Watchdog (payload watchdog) Sensor type = 23h Watchdog 2 Event Reading type code = 6Fh Sensor specific Only offset 0,1,2,3,8 are used See IPMI v2.0 table 42-3, Sensor type code 23h (Watchdog 2) for sensor definition Discrete General health status, Aggregation of critical sensor This list is flexible and could be adjust based on customer requirements Sensor type = 24h Platform Alert Event Reading type code = 03h Digital Discrete Only offset 0,1 are used See IPMI v2.0 table 42-3, Sensor type code 24h for sensor definition Discrete IPMB-0 fault detection sensor Sensor type = F1h PICMG Physical IPMB-0 Event Reading type code = 6Fh Sensor specific See PICMG 3.0 R3.0 Table 3-69, “Physical IPMB-0 event message” Discrete IPMB-L branch from FRU0 fault detection sensor Sensor type = C3h OEM (Kontron OEM IPMB-L link state) Event Reading type code = 6Fh Sensor specific Only offset 2 and 3 are used See OEM table, Sensor type code C3h (Kontron OEM IPMB-L Link State) for sensor definition 52 AT8060 www.kontron.com