Download SPLIT SYSTEM AIR CONDITIONER
Transcript
Indoor Unit AFR509HL Thermistor (Room sensor TH2) Resistance DHKTEC-35-S6N kΩ -20°C -10° Thermistor (Coil sensor TH1) Resistance 10 ± 5% 7.9 ± 5% -20°C 6.3 ± 5% -10°C 5.0 ± 5% DHPBC-41ES-14N kΩ –20°C 40.1 ± 5% –10°C 24.4 ± 5% 0°C 15.3 ± 5% -10°C Transformer (TR) Rating ATR-H85 Primary AC 235V, 50Hz Secondary 11V, 0.727A Capacity Coil resistance 8VA Ω (at 21°C) Primary (WHT – WHT): 214 ± 10% Secondary (BRN – BRN): 1.58 ± 10% Thermal cut-off temp. Indoor Unit 9.9 ± 5% 145°C, 2A, 250V FCR512HL Thermistor (Room sensor TH2) Resistance KTEC-35-S6 kΩ 10°C 10.0 ± 4% 30°C 4.0 ± 4% 15°C 7.9 ± 4% 35°C 3.3 ± 4% 20°C 6.3 ± 4% 40°C 2.7 ± 4% 25°C 5.0 ± 4% 50°C 1.8 ± 4% Thermistor (Coil sensor TH1) Resistance PBC-41E-S14 kΩ –20°C 40.1 ± 5% 20°C 6.5 ± 5% –10°C 24.4 ± 5% 30°C 4.4 ± 5% 0°C 15.3 ± 5% 10°C Transformer (TR) Rating 40°C 3.0 ± 5% 50°C 2.1 ± 5% ATR-J105 Primary AC 230V, 50 / 60 Hz Secondary 19V, 0.526A Capacity Coil resistance 9.9 ± 5% 10VA Ω (at 21°C) Thermal cut-off temp. Primary (WHT – WHT): 205 ± 10% Secondary (BRN – BRN): 2.0 ± 10% 150°C 16