Chapter 3
Case Studies
21
Figure 5. Temperature, pressure and flow velocity along the two pipes of the counter flow
heat exchanger at different times. Note the pressure gradient in opposite direction in
the two pipes, resulting in approximately equal but opposite flow speed. As in the
case of the parallel flow heat exchanger, nearly steady state conditions are reached
within 1 s of the start of the evolution.
The file counter-currentHX.out contains the output requested. We report here only an
abridged version of the full file. The file can be read (e.g. with a spread-sheet program) to
produce more elaborate plots and further analysis of the results
counter-currentHX.out
The following is the output of the results. In our case the temperature at times 0.1, 1 and 10
sec, in the junctions 1 and 2, as a function of x for all coordinates stored in the binary storage
file.
FLOWER Version 4.4
file created at
7/12/2013 10:08:29
Storage file:
counter-currentHX.store
… (lines omitted)
junction 1
junction 2
Temperature
Temperature
Temperature
Temperature
Temperature
Temperature
[K]
[K]
[K]
[K]
[K]
[K]
1.00E-01 s
1.00E+00 s
1.00E+01 s
1.00E-01 s
1.00E+00 s
1.00E+01 s
-------------------------------------------------------------------------------------------------0.0000E+00
3.0000E+02
3.0000E+02
3.0000E+02
3.0224E+02
3.0631E+02
3.0684E+02
3.3333E-02
3.0001E+02
3.0004E+02
3.0004E+02
3.0227E+02
3.0633E+02
3.0686E+02
X
[m]
… (lines omitted)
9.9667E+00
1.0000E+01
3.0466E+02
3.0467E+02
3.1245E+02
3.1247E+02
3.1298E+02
3.1300E+02
3.1990E+02
3.2000E+02
… (lines omitted)
© CryoSoft, 2013
3.1995E+02
3.2000E+02
3.1995E+02
3.2000E+02