ZXT-MF Tension Controller Instruction
P11
Nine. Wiring
Users need to loose control panel screws when wiring. Open the control panel,
Ground
Analog input 2
Analog input 1
GND
AD2
AD1
485+
485-
GND
DA1
DA2
DA3
GND
P
N2
N1
N
L
DC0-5V
MODBUS485
24V/2A
24V/2A
communication interface
magnetic clutch & brake
power input
AC 180V-245V
50/60 HZ
shaft A output ratio
shaft B output ratio
measure tension
Ground
follow wiring diagram to connect as below.
DC0-5V
Tension detector
TO2
TO1
truncated action output
cantilever action output
0V
MI3
MI4
auto feeding/quto brake switch
red blue
prepare start
MI2
duplex exchange shaft switch
MI1
yellow
12V
GND
black
A2-
white
A2+
green
5V
red
GND
black
A1-
white
A1+
green
red
5V
ZXT-MF Tension controller
Hall switch
Tip: P-N1 and P-N2 can not both output current, when Mi2 no input, P-N1 output,
when Mi2 input, P-N2 output. Size of output tension is the same as shaft A output
ratio.