UG-492
CONFIGURING THE BOARD FOR SINGLE- OR DOUBLE-SUPPLY OUTPUT
The EVAL-ADuM4471EBZ board can be configured for an
isolated circuit with either single- or double-supply output. See
Table 1 for information about the setup of the feedback divider
resistors for the single- and double-supply configurations. For
additional applications information about the supported iCoupler
devices in these configurations, see the ADuM4470/ADuM4471/
ADuM4472/ADuM4473/ADuM4474 data sheet. Figure 12 and
Figure 13 shows the schematics for the EVAL-ADuM4471EBZ
board in single- and double-supply configurations.
The single- or double-supply configuration can be selected by
changing the output mode resistor values as described in Table 2.
Table 1. Feedback Divider Resistors Configuration
After setting the feedback divider and output mode resistors,
refer to the Single Supply or Double Supply section for additional
information about configuring the EVAL-ADuM4471EBZ board.
Configuration
3.3 V Single
5 V Single
12 V Double
15 V Double
R6
17.4 kΩ
17.4 kΩ
90.9 kΩ
90.9 kΩ
R10
0Ω
Open
0Ω
Open
R11
14.3 kΩ
14.3 kΩ
24.9 kΩ
24.9 kΩ
R15
10.5 kΩ
10.5 kΩ
10.5 kΩ
10.5 kΩ
Table 2. Output Mode Resistors Configuration
Configuration
3.3 V/5 V Single
12 V/15 V Double
±15 V Double
Rev. 0 | Page 3 of 12
R5
Open
0Ω
Open
R7
0Ω
Open
0Ω
R8
Open
0Ω
Open
R9
0Ω
Open
0Ω
R19
0Ω
Open
Open