MICRONOR INC MR320 ZapFREE® Fiber Optic Encoder System Installation Guide MR320 Electrical Connections: 1 2 3 4 5 6 7 8 9 10 11 12 J1 - Terminal A+ Line Driver (5V) A- Line Driver (5V) GND B+ Line Driver (5V) B- Line Driver (5V) GND App +24V push-pull Bpp +24V push-pull GND (power) +Vs power(+15V to +32V) Counter RESET (+24V) Shield 1 2 3 4 5 6 7 8 9 10 J2 - Terminal Divider A+ (5V) Divider A+ +24V push-pull GND Divider B+ (5V) Divider B+ +24V push-pull GND GND -10V to +10V Out (analog) GND 4-20mA Out (analog) +5V (2) 10mA max J3 RS422/485 Serial I/O GND +5V Output (10mA max) TX+ TXRCV+ RCV- 1 2 3 4 5 6 A Line Driver (5V Out) MAX4031 GND (3) B+ (4) B- (5) B GND (1) GND (6) 24V Driver 7272 TX+ (3) TX- (4) A+ (1) A- (2) A+ (7) B+ (8) RCV+ (5) RCV- (6) GND (9) J3 IMPORTANT NOTES: RS422/485 Serial Interface 9600 Baud, 1 Start, 1 Stop, No Parity +24V Supply (10) 100 ohm Line Driver outputs are short circuit protected. The 24V push-pull digital outputs are short circuit protected. Avoid any long-term short circuits on outputs. (Max 5 min) Analog output polarity (direction) may be inverted by changing the Direction parameter using the ZAPPY™ Setup Program. The analog voltage output delivers up to 10mA current and is short circuit protected. The current loop output provides 0-24mA Chassis (12) J1 Encoder DIRECT Outputs Power Supply +15V to +30V A Line Driver (5V Out) A+ (1) GND (3) B B+ (4) GND (6) 24V Driver 7272 A+ (7) B+ (8) GND (9) ±10V (8) 4..20mA (10) GND (6,9) J2 Encoder DIVIDED Outputs Analog Outputs Page 3 of 13