Download THE DL-POLY-4 USER MANUAL

Transcript
c
°STFC
Appendix D
Message 340: error - invalid integration option requested
DL POLY 4 has detected an incompatibility in the simulation instructions, namely that the requested integration algorithm is not compatible with the physical model. It may be possible to
override this error trap, but it is up to the user to establish if this is sensible.
Action:
This is a non-recoverable error, unless the user chooses to override the restriction.
Message 350: error - too few degrees of freedom
This error can arise if a small system is being simulated and the number of constraints applied is
too large.
Action:
Simulate a larger system or reduce the number of constraints.
Message 360: error - degrees of freedom distribution problem
This should not happen.
Action:
Report problem to authors immediately.
Message 380: error - simulation temperature not specified or < 1 K
DL POLY 4 has failed to find a temp directive in the CONTROL file.
Action:
Place a temp directive in the CONTROL file, with the required temperature specified.
Message 381: error - simulation timestep not specified
DL POLY 4 has failed to find a timestep directive in the CONTROL file.
Action:
Place a timestep directive in the CONTROL file, with the required timestep specified.
Message 382: error - simulation cutoff not specified
DL POLY 4 has failed to find a cutoff directive in the CONTROL file.
Action:
Place a cutoff directive in the CONTROL file, with the required forces cutoff specified.
Message 387: error - system pressure not specified
The target system pressure has not been specified in the CONTROL file. Applies to NPT simulations only.
247