4.10.23. Seismic loads
The seismic loads are taken into account according
to the Response Spectrum Analysis method.
This method requires a previously calculated
number of undamped free vibration frequencies
and the corresponding mode shapes.
Based on these vibration mode shapes AxisVM generates equivalent static loads
(for each vibration mode shape) which are then applied to the model in a static analysis.
Then internal force results obtained for each mode shape are summed using to the method
described in design code specifications.
Seismic analysis can be performed based on the following design codes:




Design codes
Eurocode 8 (EN 1998-1:2004)
Swiss code (SIA 261:2003)
German code (DIN 4149:2005-04)
Italian code (OPCM 3274)
The program performs only the analysis described below. Any other supplementary
analysis required by the design codes must be completed by the user. AxisVM can calculate
extra torsional moments due to random eccentricities of masses and check the sensitivity of
stories to second order effects.
Seismic load
generation, setting
parameters
These are the steps of creating seismic loads and setting response spectrum parameters:
1. Calculate the first n vibration mode shapes and frequencies.
Check the table of seismic equivalence coefficients in X, Y, Z directions in the Table
Browser. Vibration results will appear only if you the Vibration tab is selected.
 Each design code requires that the mode shapes must represent a certain ratio of the total mass.
E.g. In Eurocode 8 the requirement is ε ≥ 0.9 (the sum of the coefficients must represent at least
90% in each direction) and every mode shape having a coefficient larger that 5% in any
direction must be included.
The individual mode shapes can be turned on or off. Mode shapes turned off are not used
when calculating seismic loads.
After right-clicking any cell of the the Active
column the popup menu appears. Choosing Turn
on/off mode shapes displays a dialog.
Mode shapes under user-defined threshold values
can be turned off. The program can be set to
reapply this filtering based on X, Y and Z automatically after every vibration analysis.