Download User's Manual
Transcript
User’s Manual e6 261 4.10.23. Seismic loads The seismic loads are taken into account according to the Response Spectrum Analysis method. This method requires a previously calculated number of undamped free vibration frequencies and the corresponding mode shapes. Based on these vibration mode shapes AxisVM generates equivalent static loads (for each vibration mode shape) which are then applied to the model in a static analysis. Then internal force results obtained for each mode shape are summed using to the method described in design code specifications. Seismic analysis can be performed based on the following design codes: Design codes Eurocode 8 (EN 1998-1:2004) Swiss code (SIA 261:2003) German code (DIN 4149:2005-04) Italian code (OPCM 3274) The program performs only the analysis described below. Any other supplementary analysis required by the design codes must be completed by the user. AxisVM can calculate extra torsional moments due to random eccentricities of masses and check the sensitivity of stories to second order effects. Seismic load generation, setting parameters These are the steps of creating seismic loads and setting response spectrum parameters: 1. Calculate the first n vibration mode shapes and frequencies. Check the table of seismic equivalence coefficients in X, Y, Z directions in the Table Browser. Vibration results will appear only if you the Vibration tab is selected. Each design code requires that the mode shapes must represent a certain ratio of the total mass. E.g. In Eurocode 8 the requirement is ε ≥ 0.9 (the sum of the coefficients must represent at least 90% in each direction) and every mode shape having a coefficient larger that 5% in any direction must be included. The individual mode shapes can be turned on or off. Mode shapes turned off are not used when calculating seismic loads. After right-clicking any cell of the the Active column the popup menu appears. Choosing Turn on/off mode shapes displays a dialog. Mode shapes under user-defined threshold values can be turned off. The program can be set to reapply this filtering based on X, Y and Z automatically after every vibration analysis.
Related documents
MyAxisVM
Finite Wordlength Realizations Toolbox User's Guide v 0.99
AxisVM
DeepView – The Swiss-PdbViewer User Guide v. 3.7
Advertencia
WOODexpress user's Manual - RUNET structural engineering
ConSteel 8 User Manual
未命名 -1 - Lumsing
Comment concevoir et réaliser des installations solaires
Untitled
Part 2: PowerFrame Reference Manual
Murray 612100x30NA Owner`s manual