When the battery does not have enough charge to power the
eTRV motor, the red LED light will flash once every five seconds.
At this point, the eTRV’s stem will automatically retract so heating
will not be controlled.
Technical information
Radio remote control
Radio range
Protocol
Temperature range
Frost-protection temperature
Temperature range for storage
Temperature range working
Maximum circulation temp.
Application group
Zone type
Battery power
Battery life in use
Size without base-ring (HxWxD)
Size with base-ring (HxWxD)
Protection class
FSK, 434.3MHz
Approx. 25m in open air
OpenThings
10°C to 24°C
10°C
-20°C to +60°C
+5°C to +40°C
90°C
Central Generation
Maintained or Intermittent
Two 1.5V AA alkaline LR6
Up to 1½ years
103 x 45 x 45 mm
120 x 45 x 45 mm
IP20
This device meets the regulatory requirements for CE marking.
It complies with the R&TTE Directive.