Download Installation and Operating Instructions
Transcript
T70si VOLTAGE AND AMPERAGE REFERENCE The electrical rating of the shower is shown on the rating label within the unit (see electrical connections). The table below can be used to ascertain amperage given the unit voltage. NOTE: The elements on UK models are to 240V specification and will give a lower kW rating if the voltage supply is below 240V. It is important to ensure that the supply voltage is the same as that shown on the rating label inside the unit. If not, then these tables will become invalid. Important: All wiring MUST conform to local regulations. If in any doubt always consult a qualified electrician. Amperage chart (UK and export models) Unit voltage 3 4 5 240 230 220 210 12.5 13.0 13.6 14.3 16.6 17.4 18.2 19.0 20.8 21.7 22.7 23.8 Rating (kW) 6 7 7.5 25.0 26.1 27.3 28.6 29.2 30.4 31.8 33.3 31.2 32.6 34.0 35.7 Cable sizes Amperes Cable size(mm2) Up to 13 13 - 20 20 - 26 26 - 52 1.5 2.5 4.0 6.0 - 10.0 19 8 8.5 9.5 10 33.3 34.8 36.6 38.0 35.4 36.9 38.6 40.4 39.6 41.3 43.0 45.2 41.7 43.5 45.5 47.6