Error diagnosis
6
ERROR DIAGNOSIS
Failures are to be corrected only by expert skilled personnel.
6.1
Failure at restart
FAILURE
CAUSE
REMEDY
No indication on the control- No mains or control voltage Check the voltage, mains
and control fuses
ler display,
no indication of the pilot
lamps
07/2002
Ventilators switched off,
error message circulating- /
exhaust air after about 20
sec.
(flow switch not in resting
position)
a.) Install flue interrupter in
user’s extraction installation
b.) * Flow switch doesn’t
react
b.) * Check the flow switch,
measuring hose and measuring set
c.) Motor protection switch
has triggered
c.) Press on-key; check
motor protection switch
a.) Door opened
Ventilation in operation
heating disconnected,
(circulating air fan off, warn- b.) Door switch reacts at
closed door
ing sound off)
a.) Close the door
Ventilation in operation,
heating connected,
(no heating up)
a.) See operating instructions of the controller
a.) Error message at the
temperature controller
b.) Check the door switch
and control disc
b.) Rated value on the tem- b.) Check the rated value
perature controller is lower on the controller
than real value
Ventilation in operation,
heating disconnected,
error message of the Temperature and warning sound
is on
Operating Instructions for Dryers for coating materials LTU 60/60 (Serie 2000)
P:\FM\LTU 60-60\Stammdatei_GB.fm
a.) User’s extraction installation without flue interrupter (fixed connection)
a) Sensor breakage of the a.) Check the temperature
temperature sensor (Pt100) sensor
of the temperature limit cutout (TLC)
b.) * TLC has disconnected b.) ** Check the setting;
press the reset keys on TLC
and on the switchboard
c.) * Safety temperature lim- c.) ** Press the reset key on
iter (STL) has disconnected STL
69 of 88