Download OPERATORS MANUAL
Transcript
TRAK-IT TOOL MODEL C3, C3 ST TROUBLESHOOTING SYMPTOM POSSIBLE PROBLEMS SERVICE 1a. Inoperative indicator lights on charger. 1a. Try Battery in tool after 3 hours on charge cycle. If tool functions properly charger lights are not working correctly. Replace charger, or monitor charging time to ensure Battery Cell has adequate time for recharging. It's normal for Battery to feel warm after properly charging. 1b. Damaged charger. 1b. Discontinue use immediately and unplug from power source. Replace charger and tag or dispose of charger to prevent accidental reuse or connection to power source. 2a. Red and green LEDs on charger are blinking alterately. 2a. Battery is hot. 2a. Remove battery from charger and allow to cool. 2b. Red and green LEDs on charger are blinking simultaneously. 2b. Battery damaged or cycle life exhausted. 2b. Replace Battery . 1a. Battery is not charged. 1a. Charge Battery according to Operating Manual. Preparing Tool for Operation – Battery/Charger Problems 1. Battery Cell does not appear to accept charge. Green charger light does not come on after several hours. Normal Stage of Operation 1. Fan does not run. 1b. Battery Terminals or Handle battery contacts are oily, dirty, or corroded. 1b. Clean Battery Cell terminals Clean Handle Battery Cell contacts as required 1c. There is electrical short somewhere. 1c. The tool must be looked into by an Authorized Powers Fasteners Service Technician. 2. Fan does not run, or runs slower than normal. 2. Battery is discharged 2. Charge Battery Cell. 3. Fan runs intermittently. 3. Battery is loose or contacts are bent. 3. Snap battery back into its locked position. Bend contacts back into proper position. 1a. Lockout Bar is stuck in lockout position. 1a. Check safety cam bushing screw for excessive tightness. Open nose piece door if necessary and clean out build-up of debris from track 1b. Contact Arm is bent, or build-up of debris in track restricts operation. 1b. Inspect Contact Arm for cleanliness and possible damage. Clean track with cloth. If Contact Arm is damaged return to Authorized Powers Fasteners Customer Service Representative for Service. 1c. Follower is not behind strip. 1c. Put follower behind strip. 1d. Cylinder head O-Ring pinched. 1d. Contact Authorized Powers Fasteners Customer Service Representative for service. 2a. Fuel Cell is empty. 2a. Replace Fuel Cell. 2b. Spark wire out of spark plug. 2b. Contact Authorized Powers Fasteners Distributor Customer Service Representative for service. 2c. Spark does not occur. 2c. Contact Authorized Powers Fasteners Customer Service Representative for service. 19 Pre-Combustion/Combustion Stage of Operation 1. Contact Arm does not depress fully--tool does not operate. 2. Tool will not cycle--fan runs. 19