Installation Connections 4.2 4 Connections The following sections describe the connections of PHC11A. [1] [2] [3] [4] [5] [6] [7] [8] [9] 60216AXX Figure 9: Connection assignment of PHC11A [1] [2] [3] [4] [5] [6] [7] [8] [9] 4.3 -20x1 -20X2 -20X13 -20x14 -30X5 -10X13 -10X1 -10X5 -0X1 Connection for ProfiBus out (M12 5-pole, B-coded socket) Connection for ProfiBus in (M12 5-pole, pins B-coded) Connection for RS232 service (M12 5-pole, pins A-coded) Connection for RS485 service (M12 5-pole, socket A-coded) Connection for I/O field control (M23, 12-pole, socket 0°-coded) Connection for I/O frequency inverter (M23 12-pole, socket 0°-coded) Connection for motor connector (HAN Q8) Connection for braking resistor (HAN Q5 socket) Connection for supply system lead (HAN Q8 pins) Wiring diagrams Assignment -20X2: ProfiBus out, M12 B-coded (socket) 3 4 2 1 60252AXX Figure 10: ProfiBus out, M12, 5-pole, B-coded (socket) PIN Assignment Function 1 +5 V Supply voltage 2 A Data line - 3 DGND Reference potential 4 B Data line + 5 N.C. Operating Instructions – MOVIPRO® PHC11A-A040M1-P00K-01 21