Download Operating Instructions - Pdfstream.manualsonline.com

Transcript
Electrical connections
N
GB
400V 3N~H05RR-F
5x2.5 CEI-UNEL 35363
L1 L2 L3
1
3
5
The cooker must be connected to the mains electricity
supply. It is designed to operate with alternating
current at the voltage and frequency indicated on the
data plate (see the following page).
The hob is connected to the cooker using a special
connector.
The terminal board is designed for a 400 V threephase connection (see diagrams below).
2
4
BUILT-IN HOB
Only on
certain models
P
N
WHITE
RED YELLOW BLUE
L1
GREEN
L2
BUILT-IN COOKER
Replace the metal protection after performing all the
necessary hob connections. If the hob is removed
from its position, the red cap which was originally
protecting the red connector must be replaced.
If the electrical system has other characteristics (see
diagrams below), carry out the electrical connection
using the connection supports provided in the box P.
N
2
4
N
1
3
5
400V 2N~H05RR-F 4x4
CEI-UNEL 35363
L1 L2
1
3
5
2
4
2. Install the power supply cable by loosening the
cable clamp screw and the wire contact screws L-N. Connect the wires to the corresponding terminals:
the Blue wire to the terminal marked (N), the Brown
wire to the terminal marked (L) and the Yellow Green
wire to the terminal marked
.
230V ~H05RR-F 3x4
CEI-UNEL 35363
L
Fitting the power supply cable
1. Open the terminal
board by inserting a
screwdriver into the side
tabs of the cover. Use
the screwdriver as a
lever by pushing it down
to open the cover (see
diagram).
L3
3. Secure the power supply cable by fastening the
clamp screw.
4. Close the cover of the terminal board.
3