INDOOR UNIT
Mounting the installation plate and screw position
Installation Place
• A place which provides the spaces around the indoor unit as shown in the
diagram.
• A place where there are no obstacles near the air inlet and outlet.
• A place which allows easy installation of the piping to the outdoor unit.
• A place which allows the front panel to be opened.
(Unit : mm)
(700)
150
230
EN
(600)
• Direct sunlight to the indoor unit’s wireless receiver should be avoided.
• The microprocessor in the indoor unit should not be too close to RF
noise sources.
(For details, see the owner’s manual)
m
90
560
272
on the wall
1. Securely fit the installation plate onto the wall by screwing it in the upper
and lower parts to hook up the indoor unit.
2. To mount the installation plate on a concrete wall with anchor bolts, use
the anchor bolt holes as illustrated in the below figure.
3. Install the installation plate horizontally in the wall.
45
PT
PL
CZ
RU
Installation plate
(Keep horizontal direction)
on
pti
ce
ran
60
DE
When the installation plate is directly mounted
Re
Remote
control
IT
Floor
7
45
90
(20
5)
15
7m
m
Wall
15
(Top view)
7
FR
15
• A place where there are no obstacles such as a curtain that may block the
signal from the remote control.
• Do not install the remote control in a place exposed to direct sunlight or
close to a heating source such as a stove.
• Keep the remote control at least 1 m apart from the nearest TV set or
stereo equipment (This is necessary to prevent image disturbances or
noise interference).
• The location of the remote control should be determined as shown below.
(Side view)
ES
15
Remote control
Indoor unit
670
590
CAUTION
Anchor bolt
CR
ge
Remote control
Reception range
Projection
15 mm or less
∅5 mm hole
* : Axial distance
7
Cutting a Hole and Mounting
Installation Plate
(Side piping)
CAUTION
GR
Failure to firmly install the unit may result in personal injury and property
damage if the unit falls.
SV
• In case of block, brick, concrete or similar type walls, make ∅5 mm holes
in the wall.
• Insert clip anchors for appropriate mounting screws 7.
60
45
DK
RO
60
100
(Bottom piping)
100
FI
NO
45
45
45
100
TR
NL
Clip anchor
(local parts)
Cutting a hole
(Rear piping)
Mounting screw
∅4 mm x 25 s
HU
BG
: Pipe hole (∅65 mm)
EE
70
LV
1. After determining the pipe hole position, drill the pipe hole (∅65 mm) at a
slight downward slant to the outdoor side.
SK
NOTE
• When drilling a wall that contains a metal lath, wire lath or metal plate, be
sure to use a pipe hole brim ring sold separately.
SI
4