Download INSTALLATION MANUAL
Transcript
INDOOR UNIT Mounting the installation plate and screw position Installation Place • A place which provides the spaces around the indoor unit as shown in the diagram. • A place where there are no obstacles near the air inlet and outlet. • A place which allows easy installation of the piping to the outdoor unit. • A place which allows the front panel to be opened. (Unit : mm) (700) 150 230 EN (600) • Direct sunlight to the indoor unit’s wireless receiver should be avoided. • The microprocessor in the indoor unit should not be too close to RF noise sources. (For details, see the owner’s manual) m 90 560 272 on the wall 1. Securely fit the installation plate onto the wall by screwing it in the upper and lower parts to hook up the indoor unit. 2. To mount the installation plate on a concrete wall with anchor bolts, use the anchor bolt holes as illustrated in the below figure. 3. Install the installation plate horizontally in the wall. 45 PT PL CZ RU Installation plate (Keep horizontal direction) on pti ce ran 60 DE When the installation plate is directly mounted Re Remote control IT Floor 7 45 90 (20 5) 15 7m m Wall 15 (Top view) 7 FR 15 • A place where there are no obstacles such as a curtain that may block the signal from the remote control. • Do not install the remote control in a place exposed to direct sunlight or close to a heating source such as a stove. • Keep the remote control at least 1 m apart from the nearest TV set or stereo equipment (This is necessary to prevent image disturbances or noise interference). • The location of the remote control should be determined as shown below. (Side view) ES 15 Remote control Indoor unit 670 590 CAUTION Anchor bolt CR ge Remote control Reception range Projection 15 mm or less ∅5 mm hole * : Axial distance 7 Cutting a Hole and Mounting Installation Plate (Side piping) CAUTION GR Failure to firmly install the unit may result in personal injury and property damage if the unit falls. SV • In case of block, brick, concrete or similar type walls, make ∅5 mm holes in the wall. • Insert clip anchors for appropriate mounting screws 7. 60 45 DK RO 60 100 (Bottom piping) 100 FI NO 45 45 45 100 TR NL Clip anchor (local parts) Cutting a hole (Rear piping) Mounting screw ∅4 mm x 25 s HU BG : Pipe hole (∅65 mm) EE 70 LV 1. After determining the pipe hole position, drill the pipe hole (∅65 mm) at a slight downward slant to the outdoor side. SK NOTE • When drilling a wall that contains a metal lath, wire lath or metal plate, be sure to use a pipe hole brim ring sold separately. SI 4 Toshiba 1112150201 (EN)