Download WiFly Command Reference, Advanced Features and
Transcript
WiFly Command Reference, Advanced Features & Applications User’s Guide <2. 23> show t Time NOT SET UpTime=8 s <2. 23> time <2. 23> show t Time=08:51:31 UpTime=15 s Note: The module must be associated with a network for the module to contact the sNTP server. The module can also be configured to get the time whenever it powers up using the set time enable 1 command. If you set the time enable to a value greater than 1, the module pulls the time continuously every <value> minutes. For example, to configure the module to get time upon power up, see the following example: <2. 23> set time enable 1 AOK <2. 23> get time ENA=1 ADDR=129.6.15.28:123 ZONE=7 To view a complete listing of the time variable, use the following command: <2. 23> show t t Time=09:02:10 UpTime=653 s RTC=1293567548 Restarts=1 Wake=6 RAW=2345ab Note: 3.9 The RAW value is the 64-bit hex RAW value of the RTC, which ticks at 32,768 Hz. TIME STAMPING PACKETS You can use the time stamping feature to append 8 bytes to a TCP or UDP packet automatically. The set ip flags 0x87 command enables the time stamp and keeps other default settings). The time stamp bits from MSB to LSB are: User’s TCP or UDP packet data 63..56 55..48 47..40 39..32 31..24 23..16 15..8 7..0 The 8 bytes represents the 64-bit raw value of the real-time clock register. The data is appended before calculating the TCP checksum so that the data passes through the TCP stack correctly. This register counts at 32,768 Hz. If the timeserver function is enabled, the RTC should accurately reflect the real time. This register also counts when the module is in Sleep mode. DS50002230A-page 68 2014 Microchip Technology Inc.