Transcript
STRMC ( Q ) = Ntypes Ntypes ∑ ∑ i =1 coeff ii = j =1 ( ) ∑ ∑ coeff ij (Q ) E3 j =i , ij j =i 2c c b b j , i j i Ntypes Ntypes ∑ ∑ coeff i ij 2 Ntypes Ntypes i ∑ ∑ coeff S i ci2 b i where coeff ij = Ntypes Ntypes ci c j bi b j Sij (Q) = ij j =i where Q is the scattering vector, ci and cj are the molar fractions and bi and bj s are the (neutron) scattering length of the components. For X-ray the formula is very similar, only instead of b the Q-dependent X-ray scattering coefficient f(Q) has to be used. Both the partial and total S(Q) and F(Q) functions have to tend to 0 at large distances, and the coefficients are normalized the way that their sum is one. The calculated and the measured data are compared by calculating the χ2 of the data set i: 2 E4 SiC (Qk ) − SiE (Qk ) ) ( ∑ χ i2 = k 2 σ i where k is going through the points of the data set. Then a chosen number of atoms are moved in the configuration. It has to be noted, then the more atoms are moved the less likely that the move will be accepted due to the possible violation of the hard sphere cutoff and the largest change in the calculated data, but if it is accepted then the configuration changes more rapidly mapping quicker the available configuration space. the number of moved atom can be arbitrary when running normal, atomic RMC (either for atomic systems or for molecules kept together with FNC), in case of molecular RMC it has to match the number of atoms in the molecule, see section I.D. The new χ2 is calculated, and if it is lower, than the old one, then the move is accepted. If not, then the move is only accepted with exp[-(χnew2 –χold2)] probability. If there are too-close atoms in the configuration (atoms closer, than their hard sphere cutoff values), and the move is moved them above the hard sphere cutoff, or at least their distance increased, then the move accepted regardless the change in the χ2. Repeating this procedure, we arrive at a configuration hopefully producing a calculated data very close the experimental one, and therefore we have a 3-dimensional configuration, which is the good representation of the real system. There can be used neutron, X-ray and EXAFS experimental data for the fitting, and total or partial g(r) functions as well, as many as we like. The EXAFS data calculation is a bit different from the others, will be discussed below. B. The units used The RMC program is traditionally using Ångstrom to measure distance, and Å-1 for the inverse space. Ångstrom is displayed in file headers and printouts. Regardless of this, data can be given in other units, but the direct and inverse space data has to be consistent. If potential is used, then the non-bonded LJ sigma parameter has to be given in Angstrom in the *.dat file, but due to the fact, that the GROMACS topology file format is adopted, in the *.top and *.itp files the GROMACS units, namely nm for distance has to be used in the topology and include topology files. Energy related parameters are given in kJ/mol. C. The ‘tooclose’ atoms, moveout option In RMC the atoms are represented as hard spheres having a hard sphere cutoff distance specified in the *.dat file for each atom type pair (partials). It can happen, that the initial configuration does not satisfy the cutoff, and some of the atoms are closer to each other, than their cutoff distance. These are the “tooclose’ atoms. To facilitate the elimination of these atom pairs, the moveout option in the *.dat file can be switched on. In this case the moved atoms are chosen in TOO_CLOSE_FRACTION*100 % of the moves from the 2