powercompact 4.2 Switching the controller off The unit can be switched OFF using the keypad, the digital input or the supervisory system. In this operating mode, the display will be show the temperature selected for the parameter ‘/tI’, alternating with the message OFF. Origin Digital input Priority Priority 1 Keypad Supervisor Priority 2 Priority 3 Note Disables ON/OFF from the keypad and supervisor In the OFF status, the following are disabled: • compressor control (sopped and pump down valve closed); • defrost (cyclical and manual); • fan control; • fan control for low relative humidity (if enabled); • continuous cycle; • autostart of the pump down function (if enabled); • condenser fan control (if enabled); • all the alarms (probe, high and low temperature, from external digital input, low pressure ...); • all the signals (defrost timeout, high condensing temperature pre-alarm); • buzzer (OFF) and alarm relay (no-alarm status); • HACCP control; • generation of the defrost requests based on the defrost interval; • generation of the defrost requests based on the set time bands; • generation of the defrost requests based on the compressor running time (if enabled); • generation of the defrost requests from digital input (if enabled); • enable defrost from digital input (if enabled); • direct/reverse-cycle operation from digital input (if enabled). While the following are enabled: • modification and display of the frequent and configuration parameters and the set point; • ON/OFF of auxiliary relay 1 (set as LIGHT or AUX); • ON/OFF of auxiliary relay 2 (set as LIGHT or AUX); • selection of the probe displayed (model M only); • door switch (with compressor and fan shutdown) limited to the management of the light; • remote ON/OFF; • curtain switch, limited to the management of the light; • door switch (with fan shutdown only) limited to the management of the light; • updating of the defrost interval timer “dI”. Note: In the OFF status, the defrost interval ‘dI’ is always updated, so as to maintain the regularity of the interval. If a defrost interval expires during the OFF status, this event is saved and, when controller is switched back ON, a defrost request is generated. The controller switches from ON to OFF with the following sequence: • the compressor protection times are observed; • the pump down procedure is performed (if enabled); • the defrost is forced OFF and will not resume when switched back ON; • the continuous cycle is forced OFF and will not resume when switched back ON. The controller switches from OFF to ON with the following sequence: • the compressor protection times are observed; • the defrost on start-up (if enabled) is not performed, as this in fact refers to power-up; • the compressor and fan delays on start-up are not set. code +030220371 – preliminary version dated 8/08/03 6