Download PULSAR 2 User Guide

Transcript
Main menu (battery is disconnected)
Main menu consist of 10 windows.
• M 1-8 processes memory, formatting/regeneration and battery test
Memory of the processes M1-8
Memory number – a digit in the right down corner on display.
There are 8 memories. Each can save:
Process parameters
Main parameter is charging/discharging current. at the complex processes (discharging/charging,
charging/discharging) there is a possibility to set up different value of charging/discharging current.
Work mode
discharging – Disch., charging – Charge,
discharging /charging – Dis/Ch., charging/discharging – Ch/Dis.
Cell Type
Ni-Cd, Ni-MH, Pb-bat, RAM, Li-Ion, Li-Pol, Li-Ta, Li-Ph
Info window (battery is disconnected)
To open information window press the M key.
V b = 1 2 , 5 V
M e m
Vb=12,5V
Tc=23,7
Mem
2,131Ah
-
T c = 2 3 , 7
2 , 1 3 1 A h
supply voltage
battery pack temperature (--,- - sensor not connected)
saved data from 8 previous processes
energy measure from last process
To read data from 8 previous press the E key.
M 8
M e n u
M8
16
Ni-Cd
Menu
-2,131Ah
1 6
N i - C d
2 , 1 3 1 A h
-
save no. 8
amount of cells
cell type
return to main menu (E)
energy, mark (-) means discharge
Info.
Battery
disconnected
Keys
+ or –
M
Function
change program
info window
Info window
M
E
+ or –
E
M
return to main menu
saved data from 8 previous processes
change save no.
return to main menu
return to info window
Saved data