Care and maintenance
6
Clean the glue channel of metering rod (3) whilst the glue is still warm.
For example, the slot by means of a piece of veneer edging and the bore with a screw driver.
DANGER
Danger of burns!
Always wear heat protection gloves
when working at the metering rod.
3
3
Heat up nozzle (29).
=
Switching on heaters
Temperature reached; green light on
.
29
Re--assembly in reverse order.
Connect metering rod (3) to cylinder (11) by means of ball head knob (45).
45
3
11