CABINET STYLE MICROPROCESSOR
WATER SOFTENER
PERFORMANCE DATA SHEET
Automatic
Model No.
AS1052TMP960
Capacity & Salt
Dosage
Recommended
Maximum
Service Flow
Rate
Flow
LPM
Minimum
Maximum
gram/kg
gram/kg
Cont.
1820/3
3640/12
37
Pipe Size
Resin
Volume
Approx.
Shipping
Weight
(kg)
Space
Required
Inlet
Outlet
Drain
mm
mm
Litres
Per Kg
metres
25
12
52
70
0.70
0.60
1.58
Peak
52
WxDxH
Peak flow not recommended for extended periods of time.
Brine Tank:
Poly moulded construction complete with lid
Operating Pressure:
205 - 690 kPa
Temperature:
5o x 50oC
Electrical:
240V 50Hz 3 watts maximum
Mains transformer provided
WARNING
A pressure reduction valve should be installed in areas of high water pressure (above 690kPa)
A water hammer arrestor should be installed if water hammer prevails.
Caution:
Do not use where water is microbiologically unsafe or with water of unknown quality.
FAILURE TO OBSERVE WARNINGS WILL VOID WARRANTY