Download USER GUIDE - Surgeons Choice
Transcript
Troubleshooting Malfunctions If a solution is not readily apparent, use the table below to help identify and correct specific malfunctions. After you troubleshoot the malfunction, verify that the unit completes the self-test as described in Section 4. Figure 7-1. Troubleshooting Situation Possible Cause Solution No power No power cord. Use power cord shipped with Aquamantys Pump Generator or contact Salient Surgical Customer Service to obtain new power cord. Wrong power cord utilized. Use power cord shipped with Aquamantys Pump Generator or contact Salient Surgical Customer Service to obtain new power cord. Faulty wall outlet. Insert power cord into a functioning wall outlet. Fuse drawer is open or fuses are blown. Close the fuse drawer. Replace the blown fuse(s). Refer to section 10. Wrong fuse. Use fuse listed in section 10 of this guide. Correct fuse is also listed on back panel of the unit. Unit not turned on. Switch unit on using the power switch located on the front panel of the unit. Insufficient insertion of device plug into receptacle. Ensure Aquamantys disposable bipolar device is fully inserted into device plug receptacle. Insufficient insertion of power cord into unit or wall jack. Ensure power cord is fully inserted into back of unit and wall jack. Damaged Aquamantys Pump Generator power cord. Contact Salient Surgical Customer Service to obtain a new power cord. Damaged Aquamantys disposable bipolar device power cord. Do not use device. Return the device to Salient Surgical and use new device. Pump tubing segment not inserted correctly into pump head. Remove pump tubing segment from pump head and reinsert correctly as indicated in User Guide. Saline bag positioned on side or upside down. Ensure saline bag is positioned right side up. Pump head not closed. Close the pump head prior to use. No saline source. Ensure spike at end of device tubing set is correctly inserted into a 250 ml or larger I.V. bag of sodium chloride solution (0.9%NaCI). Priming cycle not completed. Press “START PRIME” button once and ensure priming cycle completes and saline drips from both electrodes of the device. Priming button on unit pressed before the saline bag was spiked. Press “START PRIME” button once and ensure priming cycle completes and saline drips from both electrodes of the device. Inadequate supply of saline. Replace used bag of sodium chloride solution (0.9%NaCI) with a new bag. No saline when device activated 7-2