Download ROCPOLE VERSION 5.0 USER GUIDE

Transcript
SR and EX Type Poles
The tip end of each SR and EX Type pole has 4 No M24 tip ferrule assemblies. The tip
bending strength of these poles depends upon:
Tip ØMu (kNm)
Pole Tip
Diameter
(mm)
Pole only
Grade 4.6
M24 bolts
Grade 8.8
M24 bolts
450
525
540
600
615
675
690
750
110
130
140
160
170
180
185
200
54
65
68
78
80
90
90
100
110
130
140
160
170
180
185
200
765
825
840
900
915
990
1050
210
250
260
300
310
350
400
105
115
115
125
130
140
150
210
240
245
270
275
300
320
Table 2 – Tip bending strengths for SR and EX poles
Notes:
‘Tip ØMu’ = the design bending strength of the pole at the tip, based on the Grade of bolt
used in the ferrules or “pole only” when independent of the ferrules. A phi factor Ø = 0.8 has
been applied in these calculations. The lower strength option controls the adopted ØMu.
The bending strengths shown above which involve bolts assume the attached steelwork is
sufficiently stiff to adequately transfer the bolt loads. The concrete bearing surface limits the
loads in the bolts.
The 4 No tip ferrules are equally spaced on a PCD = Tip OD – 80mm. The tip ferrule
orientations are shown in drawing 90779.
13
RocPole™ V5.0 Application User Guide | Rocla Poles & Network Structures