Water Management
9
Field
Description
Slope Sensor
(IMD-600)
Select the serial number of the installed IMD-600 slope sensor that is used for
pitch and roll corrections. It is recommended that the IMD-600 be installed
parallel to the bottom of the boot. Refer to the FmX Cabling Guide for cable
layout. If the serial number does not appear in the list, make sure that the
cabling is connected to port C or port D on the FmX display.
Click Measurements to select the appropriate settings (see below).
Slope Transition Distance required to transition the plow to a different slope increment. If
Distance
you are using the Height or Pitch or Height and Pitch control type, set this
measurement to twice the length of the boot.
B
3.
Tip – If you are on particularly rough ground, you can increase this
distance to three or four times the boot length for smoother
operation of the pitch cylinder. If you want the plow to follow the
ground contours more closely, reduce this distance to the boot length
or less than the boot length.
In the Tile Plow Measurements screen (Height or Pitch and Height and Pitch control types),
set the following:
Field
Description
IMD-600
Label Faces
The direction (Up, Down, Left, Right) the IMD-600 label faces relative to the
direction the plow travels during installation.
Connector Faces The direction (Left, Right, Forward, Back) the installed IMD-600 connector
faces relative to the direction the plow travels during installation.
Pitch Offset
The amount of angle or tilt (up or down) if the sensor is not installed parallel
to the bottom of the boot.
B
Roll Correction
Tip – Adjusting the pitch offset can help correct the boot pitch if it is
not running level through the ground.
Corrects for static roll caused by minor variations in the Autopilot controller.
FmX Integrated Display User Guide