21. Tunnelling Figure 21.45. Round Trip Time Statistics table The Round Trip Time Statistics table reflects the measured RTT to each remote daemon. The minimum, average, maximum and standard deviation of times is presented. Entries with a large difference between the Transmitted and Received fields indicate potential problems. Figure 21.46. Round Trip Time Statistics form remote-ip Synopsis: IPv4 address in dotted-decimal notation IP address of remote goose daemon transmitted Synopsis: unsigned integer The number of beacon frames transmitted over the tunnel received Synopsis: unsigned integer The number of beacon frames transmitted over the tunnel minimum-rtt Synopsis: A string The Minimum Beacon Round-Trip-Time average-rtt Synopsis: A string The Average Beacon Round-Trip-Time maximum-rtt Synopsis: A string The Maximum Beacon Round-Trip-Time deviation Synopsis: A string ROX™ v2.2 User Guide 261 RuggedRouter® RX1000