Local Area Data Set
(LADS) Operation
Hardware Strapping
Both Model 3510 and 3511 DSUs can be configured
for installation at the local or remote end of a network by
setting onboard straps. The straps also allow you to
configure either type of DSU (Model 3510 or 3511) as a
LADS for connection to 4-wire metallic circuits.
You can connect 3500 Series DSUs to a 4-wire,
non-loaded metallic circuit that functions as a
point-to-point LADS. Factors that affect this type of
installation are the data rate, the distance between LADS
facilities, and the wire gauge. Table 4-2 summarizes the
typical interrelationship of these factors.
Table 4-2
3500 Series DSU LADS Connection
Wire Gauge (AWG)
Data Rate
3510-A2-GN32-70
19
22
24
26
2.4
20.0 mi
(32.2 km)
16.6 mi
(26.7 km)
12.7 mi
(20.5 km)
9.4 mi
(15.1 km)
4.8
19.4 mi
(31.2 km)
12.7 mi
(20.5 km)
9.6 mi
(15.4 km)
7.1 mi
(11.5 km)
9.6
15.2 mi
(24.5 km)
9.7 mi
(15.6 km)
7.3 mi
(11.7 km)
5.6 mi
(9.0 km)
19.2
11.8 mi
(19.0 km)
7.5 mi
(12.1 km)
5.7 mi
(9.2 km)
4.2 mi
(6.8 km)
38.4
11.2 mi
(18.0 km)
6.5 mi
(10.5 km)
4.6 mi
(7.4 km)
3.2 mi
(5.1 km)
56
9.2 mi
(14.8 km)
5.4 mi
(8.7 km)
3.8 mi
(6.2 km)
2.8 mi
(4.5 km)
64
9.2 mi
(14.8 km)
5.4 mi
(8.7 km)
3.8 mi
(6.2 km)
2.8 mi
(4.5 km)